3 alcove clearances, 4 non-combustible facing material – Napoleon Fireplaces B30NTR Manuel d'utilisation

Page 38

Advertising
background image

38

W415-1296 / 05.20.14

EN

APPLIANCE

RECESS OR
ALCOVE
AREA

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.

Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.

The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.

71.2

ENCLOSURE
AREA

5.3 ALCOVE

CLEARANCES

TOP OF

APPLIANCE

WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,

as illustrated [up to a maximum of 6” (152.4mm)]. Greater than 6” (152.4mm) protrusions are considered a

mantel and must meet the combustible mantel requirements.

71.4B

4" (102mm)

2" (51mm)

6" (152mm)

FRONT OF

APPLIANCE

4" (102mm)

2" (51mm)

NON-COMBUSTIBLE

FACING MATERIAL

0" (0mm)

FINISH

MATERIAL

NON-COMBUSTIBLE

FACING MATERIAL

FINISH MATERIAL

2" (51mm)

4" (102mm)

6" (152mm)

4" (102mm)

2" (51mm)

0" (0mm)

5.4 NON-COMBUSTIBLE FACING MATERIAL