Warning, 11 rear exit, 12 top vent – Napoleon Fireplaces B30NTR Manuel d'utilisation

Page 23

Advertising
background image

23

W415-1296 / 05.20.14

EN

90°

V

1

V

2

H

1

H

2

90°

90°

H

3

45°

18.2_3A

Example:
V

1

= 1.5 FT (0.5m)

V

2

= 5 FT (1.5m)

V

T

= V

1

+ V

2

= 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m)

H

1

= 1 FT (0.3m)

H

2

= 1 FT (0.3m)

H

3

= 10.75 FT (3.3m)

H

R

= H

1

+ H

2

+ H

3

= 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m)

H

O

= .03 (four 90° elbows + one 45° elbow - 90°)

= .03 (360° + 45° - 90°) = 6.75 FT (2.1m)
H

T

= H

R

+ H

O

= 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)

H

T

+ V

T

= 19.5FT (5.9m) + 6.5FT (2m) = 26 FT (7.9m)

Formula 1:
H

T

< 3 V

T

3 V

T

= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)

19.5FT (5.9m) = 19.5FT (5.9m)

Formula 2:
H

T

+ V

T

< 40 FT (12.2m)

26 FT (7.9m) < 40 FT (12.2m)

Since both formulas are met, this vent configuration is acceptable.

3.11 REAR EXIT

A.

From inside the fi rebox, start by removing the top defl ector. Next, insert the 4" (102mm) fl ue pipe /
gasket assembly out through the rear of the fi rebox. Secure the assembly to
the rear and top of the appliance using 4 #8 x ¾" screws supplied. Do not
overtighten. The gasket should seat evenly against the rear and top of the
fi rebox, creating an air tight seal.

B.

Re-install the top defl ector.

C.

Before attaching an elbow or rigid adaptor to the rear collar, it may be
necessary to trim the 4" (102mm) collar.

!

WARNING

FAILURE TO INSTALL THE CAP WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND

CAN CAUSE INJURY OR PROPERTY DAMAGE.

3.12 TOP VENT

A.

Remove the 7" (178mm) diameter cap from the top of the
appliance. From inside the 7" (178mm) collar remove the insulation
and retaining clip.

B.

Re-install the clip and insulation in the 7" (178mm) collar on the
rear of the appliance. Re-secure the cap on the rear collar. Press
fi rmly on the cap while securing to ensure an air tight seal. Do not
damage the gasket.

C.

From inside the fi rebox, start by removing the top defl ector.
Next, insert the 4" (102mm) fl ue pipe / gasket assembly
up through the heat shield and out through the top 7"
(178mm) collar. Secure the assembly to the rear and top of the
appliance using 4 #8 x ¾" screws supplied. Do not overtighten.
The gasket should seat evenly against the rear and top of the fi rebox,
creating an air tight seal.

D.

Re-install the top defl ector.

!

WARNING

FAILURE TO INSTALL THE CAP WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND

CAN CAUSE INJURY OR PROPERTY DAMAGE.

CAP C/W
GASKET

INSULATION

RETAINING CLIP