3.9 TOP EXIT VERTICAL TERMINATION

0

2.5

(0.8)

5

(1.5)

7.5

(2.3)

10

(3.1)

12.5

(3.8)

15

(4.6)

40 (12.2)

10 (3.1)

20 (6.1)

30 (9.1)

17.5

(5.3)

20

(6.1)

1.6

(0.5)

1.6 (0.5)

38.3 (11.7)

90°

V

1

V

2

H

1

H

2

90°

90°

90°

H

3

Simple venting configuration

(only two 90° elbows)

See graph to determine the required vertical rise V

T

for the required

horizontal run H

T

.

REQUIRED

VERTICAL

RISE IN

FEET

(METERS) V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H

T

The shaded area within the lines represents acceptable values for H

T

and H

T

(H

T

) < (V

T

)

16.3A

For vent configurations requiring more than two 90° elbows, the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet (12.2m)

Example:
V

1

= 9 FT (2.7m)

V

2

= 6 FT (1.8m)

V

T

= V

1

+ V

2

= 9FT (2.7m) + 6FT (1.8m) = 15FT (4.6m)

H

1

= 3 FT (0.9m)

H

2

= 2 FT (0.6m)

H

3

= 1.5 FT (0.5m)

H

R

= H

1

+ H

2

+ H

3

= 3FT (0.9m) + 2FT (0.6m) + 1.5FT (0.5m) = 6.5FT (2m)

H

O

= .03 (four 90° elbows - 90°) = .03 (360° - 90°) = 8.1 FT (2.5m)

H

T

= H

R

+ H

O

= 6.5FT (2m) + 8.1FT (2.5m) = 14.6FT (4.5m)

H

T

+ V

T

= 14.6FT (4.5m) + 15FT (4.6m) = 29.6 FT (9m)

Formula 1:

H

T

< V

T

14.6 FT (4.5m) < 15 FT (4.6m)

Formula 2:

H

T

+ V

T

< 40 FT (12.2m)

29.6 FT (9m) < 40 FT (12.2m)

Since both formulas are met, this vent configuration is acceptable.