Inside chase outside chase – Napoleon Fireplaces B30NTR Manuel d'utilisation

Page 35

Advertising
background image

35

W415-1296 / 05.20.14

EN

14 1/2"

368mm

2" 51mm

INSIDE

CHASE

OUTSIDE

CHASE

14 1/2"

368mm

SIDE

WALL

30 1/2" 774mm

30 1/2" 774mm

27 5/16"

694mm

30 1/2"

774mm

40 5/8"

1032mm

It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building
codes.
It is not necessary to install a hearth extension with this appliance.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor
materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower
access door and the installation of many decorative fl ashing accessories.
Combustible materials may be installed fl ush with the front of the appliance but must not cover any of the black
face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.

Minimum clearance to combustible construction from appliance and vent surfaces:

Combustible

Framing:

-

0" to stand-offs

-

1" (25mm) to bottom and sides of the vent pipe*

-

3" (76mm) to top of the vent pipe*

Combustible Finishing:

-

0" to rear

-

0" to front face top and sides

Top Exit

-

50 1/2" (1283mm) to combustible enclosure top from base of the appliance

-

54" (1372mm) to ceiling from base of the appliance

Rear Exit

-

* HORIZONTAL VENT SECTIONS:

A minimum of 1" (25mm) at the bottom and sides and 3" (76mm) at the top

of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1774 (supplied).

* VERTICAL VENT SECTIONS:

A minimum of 1" (25mm) all around the vent pipe on all vertical runs to

combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).