Installation instructions, Warning, Exhaust connection – GE GTUP240EMWW Manuel d'utilisation

Page 7: Leveling and stabilizing your appliance

Advertising
background image

Installation Instructions

7

4

EXHAUST CONNECTION

LEVEL
SIDE-TO-SIDE.

2 LEVELING LEGS

LEVEL

FRONT-TO-BACK.

DUCT TAPE OR
DUCT CLAMP

DUCT TAPE OR
DUCT CLAMP

4" METAL DUCT CUT
TO PROPER LENGTH

EXTERNAL DUCT

OPENING

For straight line installation, connect
the dryer exhaust to the external
exhaust hood using duct tape or
clamp.

5

LEVELING AND STABILIZING YOUR APPLIANCE

STANDARD REAR EXHAUST

Level and stabilizing your appliance

1. &DUHIXOO\PRYHWKHDSSOLDQFHWRLWV¿QDOORFDWLRQ*HQWO\URFN

the appliance into position. It is important not to damage the
UXEEHUOHYHOLQJOHJVZKHQPRYLQJ\RXUDSSOLDQFHWRLWV¿QDO

location.

Damaged

legs can increase appliance vibration. It

PD\EHKHOSIXOWRVSUD\ZLQGRZFOHDQHURQWKHÀRRUWRKHOS
PRYH\RXUDSSOLDQFHWRLWV¿QDOSRVLWLRQ

Note: Do not use washer cover to lift the unit.

2. To ensure the appliance is level and solid on all four legs,

WLOW WKH DSSOLDQFH IRUZDUG VR WKH UHDU OHJV DUH RȺ WKH

ground. Gently set the appliance back down to allow the

rear legs to self adjust.

:LWKWKHDSSOLDQFHLQLWV¿QDOSRVLWLRQSODFHDOHYHORQWRS

of back part of the washer lid and check it side to side,

then check front to back. Screw the front leveling legs up

or down to ensure the appliance is resting solid on all four
OHJV QR URFNLQJ RU WKH DSSOLDQFH VKRXOG H[LVW  WXUQ WKH

lock nuts on each leg up toward the base of the unit and

snug with a wrench.

Note: Keep the leg extension at minimum to prevent excessive

vibration. The farther out legs are extended, the more the unit

will vibrate.

STANDARD REAR EXHAUST

9HQWHGDERYHÀRRUOHYHO

(/%2:+,*+/<

RECOMMENDED

RECOMMENDED
CONFIGURATION
TO MINIMIZE
(;+$867%/2&.$*(

NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING

WARNING -

TO REDUCE THE

RISK OF FIRE OR PERSONAL INJURY:

• This appliance must be exhausted to the outdoors.

• Use only 4” rigid metal ducting for the home exhaust

duct.

‡ 8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO

VHPLULJLGRUIRLOW\SH GXFWWRFRQQHFWWKHGU\HUWRWKH

home exhaust duct. It must be installed in accordance

with the instructions found in “Connecting The Dryer

To House Vent” on page 8 of this manual.

• Do not terminate exhaust in a chimney, a wall, a ceiling,

JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU

or in any other concealed space of a building. The

accumulated lint could create a

potential

¿UHKD]DUG

• Never terminate the exhaust into a common duct with

a kitchen exhaust system. A combination of grease
DQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG

‡ 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW

length table. Longer ducts can accumulate lint,
FUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Never install a screen in or over the exhaust duct. This

ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG

• Do not assemble ductwork with any fasteners that

extend into the duct. These fasteners can accumulate
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

• Do not obstruct incoming or exhausted air.

• Provide an access for inspection and cleaning of the exhaust

system, especially at turns and joints. Exhaust system shall

be inspected and cleaned at least once a year.

THIS DRYER COMES READY FOR REAR

EXHAUSTING. IF SPACE IS LIMITED, USE

THE INSTRUCTIONS IN SECTION 6 TO

EXHAUST DIRECTLY FROM THE SIDES OR

BOTTOM OF THE CABINET.