Installation Instructions



EXHAUST INFORMATION (cont.)

• For every additional 90° elbow, reduce the allowable vent

system length by 10 ft.

• Two 45° elbows will be treated like one 90° elbow. For the side

exhaust installations, add one 90° elbow to the chart.

• The total vent system length includes all the straight portions

DQGHOERZVRIWKHV\VWHP WUDQVLWLRQGXFWLQFOXGHG 

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of

birds or other wildlife.

• Termination should present minimal resistance to

WKH H[KDXVW DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR

maintenance to prevent clogging.

Never install a screen in or over the exhaust duct. This

could cause lint build up.

• Wall caps must be installed at least 12 in. above ground

level or any other obstruction with the opening pointed
down.

SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and
exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end of

each section of duct must point away from the dryer.

• Do not assemble the ductwork with fasteners that extend

into the duct. They will serve as a collection point for lint.

‡ 'XFW MRLQWV FDQ EH PDGH DLU DQG PRLVWXUHWLJKW E\

wrapping the overlapped joints with duct tape.

‡+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV

1/4 inch per foot

INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation
DQGOLQWEXLOGXS

3

EXHAUST INFORMATION

WARNING -

IN CANADA AND IN

THE UNITED STATES, THE REQUIRED EXHAUST

DUCT DIAMETER IS 4 IN (102mm). DO NOT

USE DUCT LONGER THAN SPECIFIED IN THE

EXHAUST LENGTH TABLE.

8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO

• Increase the drying times and the energy cost.

• Reduce the dryer life.
‡$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

The correct exhaust installation is YOUR RESPONSIBILITY.

Problems due to incorrect installation are not covered by

the warranty.

Remove and discard existing plastic or metal foil transition

duct and replace with UL listed transition duct.

The MAXIMUM ALLOWABLE duct length and number of

bends of the exhaust system depends upon the type of
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRG ZDOOFDS 

and all conditions noted below. The maximum duct length

for rigid metal duct is shown in the following table.

27” DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

56 Feet
48 Feet
40 Feet
32 Feet

0
1
2
3

42 Feet
34 Feet
26 Feet
18 Feet

Use only for short

run installations

24” DRYER EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elbows

Rigid

Metal

Rigid

Metal

43 Feet
33 Feet
24 Feet

0
1
2

36 Feet
26 Feet
16 Feet

Use only for short

run installations

WARNING:

NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK.

CONNECTING APPLIANCE USING 4-WIRE

CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION) (Cont.)

&RQQHFWSRZHUFRUGDVIROORZV

A. Connect the 2 hot lines to the outer screws of the
WHUPLQDOEORFN PDUNHG/DQG/ 
%&RQQHFWWKHQHXWUDO ZKLWH OLQHWRWKHFHQWHURIWKH
WHUPLQDOEORFN PDUNHG1 

7. Attach ground wire of power cord with the green ground

VFUHZ KROHDERYHVWUDLQUHOLHIEUDFNHW 7LJKWHQDOO
WHUPLQDOEORFNVFUHZV  VHFXUHO\

8. Properly secure power cord to strain relief.

9. Reinstall the cover.