BATHROOM OR BEDROOM INSTALLATION

• The appliance MUST be vented to the outdoors. See

EXHAUST INFORMATIONVHFWLRQ 

• The installation must conform with local codes or, in the

absence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.

9

MOBILE OR MANUFACTURED HOME
INSTALLATION

• Installation MUST conform to the MANUFACTURED HOME

CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART
32-80
or, when such standard is not applicable, with
AMERICAN NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.

• The appliance MUST be vented to the outdoors with

the termination securely fastened to the mobile home
structure.

• The vent MUST NOT be terminated beneath a mobile or

manufactured home.

• The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the appliance securely

to the structure.

• The vent MUST NOT be connected to any other duct, vent, or

chimney.

• Do not use sheet metal screws or other fastening devices

which extend into the interior of the exhaust vent.

• See section 2 for electrical connection information.

10

ALCOVE OR CLOSET INSTALLATION

• If your appliance is approved for installation in an alcove

or closet, it will be stated on a label on the appliance

back.

• TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE

FROM ACCUMULATING AND TO MAINTAIN DRYING
()),&,(1&<7+,60$&+,1(0867%((;+$867('

OUTDOORS.

• Do not install this appliance with less than the minimum

clearances shown above.

&216,'(5$7,210867%(*,9(1723529,'(

ADEQUATE CLEARANCES FOR INSTALLATION AND
SERVICE.

WARNING:

DO NOT INSTALL THIS

APPLIANCE IN A CLOSET WITH A SOLID DOOR.

1”

0”

0”

0”

0”

1”

DOOR VENTILATION OPENING (27” MODELS)

A minimum of 120 square inches of opening, equally divided
at top and bottom, is required. Air openings are required to
be unobstructed when a door is installed. A louvered door
with equivalent air openings for the full length of the door
is acceptable.
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 120
square inches.

DOOR VENTILATION OPENING (24” MODELS)

A minimum of 72 square inches of opening is required. Air
openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for
the full length of the door is acceptable.
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 72
square inches.

6T,Q

6T,Q

27” Model

48 Sq. In.

24 Sq. In.

24” Model