Wiring diagrams – Robertshaw RS6320C Manuel d'utilisation

Page 8

Advertising
background image

8

Compressor

Contactor

Fan

Relay

G

O

B

Y1

W1

Y2

W2

E

RH/R

RC

C

L

Transformer

Hot

120 Vac

Remove jumper if

separate cooling

transformer is

present.

When used as

Non-Heat Pump With Battery Backup

Make certain the HP switch is in the Non-HP position.

24 Vac

Second

Stage Cool

Second

Stage Heat

First Stage

Heat

Compressor

Contactor

Reversing

Valve

Fan

Relay

G

O

B

Y1

W1

Y2

W2

E*

RH/R

RC

C

L

Transformer

Hot

120 Vac

Remove jumper if

separate cooling

transformer is

present.

When used as

Heat Pump with Cool Active Reversing Valve With Battery Backup

Make certain the HP switch is in the HP position.

24 Vac

Compressor

Fault Output

(24VAC)

Second

Stage Cool

Second

Stage Heat

Emer Heat

* Insert jumper between W2 and E if emergency heat source is same as second stage

Compressor

Contactor

Reversing

Valve

Fan

Relay

G

O

B

Y1

W1

Y2

W2

E*

RH/R

RC

C

L

Transformer

Hot

120 Vac

Remove jumper if

separate cooling

transformer is

present.

When used as

Heat Pump with Heat Active Reversing Valve With Battery Backup

Make certain the HP switch is in the HP position.

24 Vac

Compressor

Fault Output

(24VAC)

Second

Stage Cool

Second

Stage Heat

Emer Heat

* Insert jumper between W2 and E if emergency heat source is same as second stage

Wiring Diagrams