Robertshaw RS6320C Manuel d'utilisation

Page 11

Advertising
background image

11

Default Settings for RS5220C, RS6220C
and RS6320C

The RS5220C and RS6320C series are programmable thermostats

and are preprogrammed with a recommended schedule. The schedule is

designed to lower energy costs year-round.

Setting Time and Day for the RS5220C,
RS6220C and RS6320C

To adjust the time and day settings press the SET TIME button. The hour

will flash. To change the settings:
1. Use the and buttons to change the flashing number.
2. Press the SET TIME button to move through hours, minutes and days

of week.

3. Make changes as needed. They will be saved automatically.
NOTE: The thermostat will not correct for Daylight Saving Time.

Installation Test Utility

WARNING: The installation test procedures

can damage the heating/cooling equipment

if used incorrectly. These procedures

should only be performed by trained

HVAC personnel.

The following instructions may be used to test the heating/cooling

system for correct function.
To enter the test mode press and hold and

for five seconds.

Short Cycle protection is disabled when using the test utility.
Push the and or Start/Stop schedule buttons at any time to

exit test mode.
In the test mode:
Press to force the fan on or off.
Pressing

repeatedly will allow testing of the system modes. See

following tables. The display will show appropriate animated icons.

Temperature Settings

Winter (Heating)

Summer (Cooling)

Morning (6:00 am)

70 °F (21 °C)

78 °F (25 °C)

Day (8:00 am)

62 °F (17 °C)

85 °F (29 °C)

Evening (6:00 pm)

70 °F (21 °C)

78 °F (25 °C)

Night (10:00 pm)

62 °F (17 °C)

82 °F (28 °C)

Advertising