Two Stage Models RS4220C, RS5220C and RS6220C

TERMINAL

EQUIPMENT TO  

CONNECT

DESCRIPTION 

L

24V AC

Compressor Fault

Output

Connect to fault signal for input from

a compressor.

Y2

Second stage

cooling

connection.

Energizes on a call for second stage

cooling (aux.).

W2

Second stage

heat connection

Energizes on a call for second stage

heating (aux.).

E

Emergency Heat

Connection

Energizes on a call for emergency heat.

If emergency heat is the same as the second

stage then jumper E to W2.

Three Stage Models RS4320C and RS6320C

TERMINAL

EQUIPMENT TO  

CONNECT

DESCRIPTION 

E

Third stage heat

Energizes on a call for 3rd stage heat