IMPORTANT SAFETY INFORMATION

WARNING:

• Always turn off power at main fuse or circuit breaker panel before

installing, removing, cleaning, or servicing thermostat.

• Read all the information in this manual before installing this

thermostat.

• This is a 24V AC low-voltage thermostat. Do not install on voltages

higher than 30V AC.

• All wiring must conform to local and national building and electrical

codes and ordinances.

• This is a dual powered thermostat that will operate on 24V AC

or batteries.

• Do not short (jumper) across terminals on the gas valve or at the

system control to test installation. This will damage the thermostat

and void the warranty.

• Do not connect ground to any terminal in this unit.
• This thermostat is configured with automatic compressor protection

to prevent damage because of short cycling or extended power

outages. Short cycle protection provides a delay between

compressor cycles on heat pumps.

Replacing Existing Thermostat

1. Turn off power to heating and cooling system.
2. Remove cover from old thermostat to expose wires.
3. Disconnect wires one at a time from existing terminals. Use

enclosed labels to mark existing wires. Refer to cross references in

Table 1 if existing wiring does not directly match the labels.

4. Remove existing thermostat base from wall.

  Table 1

  Old Terminal 

New Label 

Description

R, RH/R, V-VR or VR-R

R/RH

24V AC Return

RC

RC

24V AC Cooling Transformer

C, X or B

C

24V AC Transformer Common Side

F or G

G

Fan Control Relay

Y, Y1 or M

Y1

1st Stage Cooling Circuit

W1 or W

W1

1st Stage Heating Circuit

Y2

Y2

2nd Stage Cooling Circuit

W2 or W-U

W2

2nd Stage Heating Control

W3

E

3rd Stage Heating Control

E

E

Emergency Heating Control