App-7

1.4.17

Effect1 Depth (Reverb Send Level)

Messages which adjust the send level for the Reverb effect.

CNTRL#

PARAMETER

DATA RANGE

91

Effect1 Depth

0...127

1.4.18

Effect3 Depth (Chorus Send Level)

Messages which adjust the send level for the Chorus effect.

CNTRL#

PARAMETER

DATA RANGE

93

Effect3 Depth

0...127

1.4.19

Effect4 Depth (Variation Effect Send Level)

Messages which adjust the send level for the Variation effect.

CNTRL#

PARAMETER

DATA RANGE

94

Effect4 Depth

0...127

If Variation Connection (page App-13) = 1 (System), this message
sets the send level for the Variation effect.
If Variation Connection = 0 (Insertion), this has no effect.

1.4.20

Data Increment / Decrement (for RPN)

Messages which increase or decrease the MSB value of Pitch Bend
Sensitivity, Fine Tune, or Coarse Tune in steps of 1.

CNTRL#

PARAMETER

DATA RANGE

96

RPN Increment

0...127

97

RPN Decrement

0...127

The data byte is ignored.
When the maximum value or minimum value is reached, the value
will not be incremented or decremented further.
(Incrementing the Fine Tune will not cause the Coarse Tune to be
incremented.)

1.4.21

NRPN (Non-Registered Parameter Number)

Messages which adjust a Voice’s vibrato, filter, EG, drum setup or
other parameter settings.

CNTRL#

PARAMETER

DATA RANGE

98

NRPN LSB

0...127

99

NRPN MSB

0...127

First send the NRPN MSB and NRPN LSB to specify the param-
eter which is to be controlled. Then use Data Entry to set the value
of the specified parameter.
* Note that once the NRPN has been set for a channel, subse-

quent data entry will be recognized as the same NRPN’s value
change. Therefore, after you use the NRPN, you should set a
Null (7FH, 7FH) value to avoid an unexpected result.

The following NRPN numbers can be received.

NRPN

DATA ENTRY

MSB LSB

MSB

PARAMETER NAME and VALUE RANGE

01H

08H

mmH

Vibrato Rate
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

09H

mmH

Vibrato Depth
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

0AH mmH

Vibrato Delay
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

20H

mmH

Filter Cutoff Frequency
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

21H

mmH

Filter Resonance
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

63H

mmH

EG Attack Time
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

64H

mmH

EG Decay Time
mm : 00H - 40H - 7FH (-64 - 0 - +63)

01H

66H

mmH

EG Release Time
mm : 00H - 40H - 7FH (-64 - 0 - +63)

14H

rrH

mmH

Drum Filter Cutoff Frequency
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number

15H

rrH

mmH

Drum Filter Resonance
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number

16H

rrH

mmH

Drum EG Attack Rate
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number

17H

rrH

mmH

Drum EG Decay Rate
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number
Applies to both Decay1 and 2.

18H

rrH

mmH

Drum Instrument Pitch Coarse
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number

19H

rrH

mmH

Drum Instrument Pitch Fine
mm : 00H - 40H - 7FH (-64 - 0 - +63)
rr : drum instrument note number

1AH rrH

mmH

Drum Instrument Level
mm : 00 - 7F (0 - max)
rr : drum instrument note number

1CH

rrH

mmH

Drum Instrument Pan
mm : 00H - 40H - 7FH

(random, left - center - right)

rr : drum instrument note number

1DH rrH

mmH

Drum Instrument Reverb Send Level
mm : 00H - 7FH (0 - max)
rr : drum instrument note number

1EH

rrH

mmH

Drum Instrument Chorus Send Level
mm : 00H - 7FH (0 - max)
rr : drum instrument note number

1FH

rrH

mmH

Drum Instrument Variation Send Level
mm : 00H - 7FH (0 - max)
rr : drum instrument note number

MSB 14H–1FH (for Drum) is valid only if the Multi Part param-
eter (page App-13) PART MODE = DRUMS 1 or DRUMS2 for
that channel. (If PART MODE = DRUM, no values will be changed.)

1.4.22 RPN (Registered Parameter Number)
Messages which offset, or add or subtract values from a Part’s pitch
bend sensitivity, tuning, or other parameter settings.

CNTRL#

PARAMETER

DATA RANGE

100

RPN LSB

0...127 (Default:7FH)

101

RPN MSB

0...127 (Default:7FH)

* Note that once the RPN has been set for a channel, subsequent

data entry will be recognized as the same RPN’s value change.
Therefore after you use the RPN, you should set a Null (7FH,
7FH) value to avoid an unexpected result.

MIDI Data Format