Installing Body Assembly in an Open 1-Sided or 2-Sided Installation

Steel framing options are available for the open 1-sided
and open 2-sided installations. For ease of installation,
Rinnai provides a steel frame as a kit. Refer to the
separate detailed instructions for assembly of the steel
frame.

To enhance the durability of any type of framing, it is
suggested that the frame is mounted on a paved slab
9.5 inches (250 mm) above unpaved ground and 5.9
inches (150 mm) above paved ground.

Prepare Framing Dimensions

If framing is made of a combustible material, ensure the following minimum framing dimensions and clearances:

Framing

Dimensions

A

21.8 in (555 mm)

B

48.3 in (1225 mm) *

C (2-sided)

18.5 in (470 mm) **

C (1-sided)

19.7 in (500 mm) **

Minimum Clearance to Combustibles

NOT ALLOWED

1.0 in (25 mm)

0

Above

Side

Below

Behind

1.2 in (30 mm)

Non-combustible cladding
is required over the entire
frame.

*

Includes 1 in (25 mm) side
clearances.

**

Includes cladding (for 1-sided unit,
this includes cladding on one side
only)

Attach Metal Lintel and Angled Clearance Brackets

Metal Lintel

Designed to sit above the appliance and replace
combustible framing in areas above the appliance.

To install:

1. Take out and undo 4 fastening screws at either end.

2. Flip side sections 180° and loosely refit screws.

3. Adjust to the desired length before tightening.

Metal
Lintels

Angled
Brackets

Open 1-sided Cabinet

1 4

Open 2-sided Cabinet

2 4

Parts Required

side sections need to
be rotated 180° and
secured into the
framing above the
appliance

WARNING

The metal lintel and angled clearance brackets are
required for installations where combustible framing is
used.

Cross members above
the appliance must be
non-combustible.
Metal lintels are
provided with the
purchase of the 1-
sided and 2-sided
fireplaces. Metal
lintels are also offered
separately (R2629).