Rinnai 4500 Manuel d'utilisation

Page 14

Advertising
background image

14

Rinnai Corporation ROF4500

Installing Freestanding or Enclosed

Masonry

Applications

Prepare Surround

Construct surround following the clearances to combustibles and minimum height from ground. The surround
must be a permanent and fixed construction.

Install Burner Assembly

Install burner assembly and fix in place with fasteners provided.

Place the cover on the burner when not in use and after it has cooled off.

Install Burn Media and Complete Gas Connection

This is common to all installations. Refer to these sections in the manual.

Prepare a gas connection opening underneath the gas supply access position. Ensure the opening is large
enough for the flexible connection to fit through.

Minimum Dimensions

21.85 in (555 mm)

46.26 in (1175 mm)

18.50 in (470 mm)

A

B

C

17.91 in (455 mm)

17.91 in (455 mm)

19.68 in (500 mm)

8.27

i

n

(2

10 m

m

)

10

.2

4 i

n

(260 mm)

12.0

1

i

n

(305

mm

)

Suggested
size for gas
connection
opening

1.38 in (35 mm)

3.15 in
(80 mm)

Gas supply opening

Non-combustible Enclosed Masonry

Freestanding

Clad Surround

Refer to the section, Guidelines for Cladding and Finishes.

recommended