Stationary Electric Air Compressor Manual

5

Move Motor/Pressure Switch to

"AUTO" position.

Turn unit off, wait 5 minutes, then

press Motor Thermal Overload until

click is heard.
Reset circuit breaker or replace fuse if

necessary, using only "Fusetron" type

T fuses.
Check for low voltage conditions.
Disconnect any other electrical ap-

pliances from circuit or operate air

compressor on its own branch circuit.

Contact your Customer Service.

The motor will start automatically

when air tank pressure drops down to

the "Cut-in" or "Start" pressure of the

Motor/Pressure Switch.

Bleed the line by moving the switch to

the "Off" position.

Remove and clean or replace.
Contact your Customer Service.

Add oil to pump

Motor/Pressure Switch turned "OFF".

Motor Thermal Overload tripped on

air compressor.

Circuit breaker tripped or fuse blown

at power source.

Motor voltage does not match power

source.

Air tank pressure achieved the "Max-

imum setting" or "Stop pressure" of

the Motor/Pressure Switch.

Pressure release valve on Motor/

Pressure Switch has not unloaded

pump head pressure.
Pilot valve's check valve stuck open.
Defective motor, or Motor/Pressure

Switch.

Low oil level (if unit is equipped with

Low Oil Sensor)

Air compressor will not start,

but motor hums, then stops.

Loose electrical connection.
Too many appliances being oper-

ated on same circuit.
Incorrect voltage, incorrect sized

circuit breaker, fuse or motor. De-

fective motor.
Defective Check Valve or Motor/

Pressure Switch.

Contact qualified electrician.
Use another circuit or remove excess

appliances from circuit.
Contact qualified electrician.

Replace.

Air compressor does not stop

even though the maximum

pressure allowed has been

reached.

Motor/Pressure Switch not operat-

ing correctly.

Replace.

Air compressor will not start.

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

REMEDY