Stationary Electric Air Compressor Manual

3

1. A qualified electrician

MUST hook up the electrical system.

a. Verify the electrical supply at the power source is off.
b. Be certain all switches on the Control Panel are in the "OFF"

position.

c. Make connections to the terminal as shown below.

PREPARATION INSTRUCTIONS

PRE-START CHECKLIST:

. Check oil level. Add if necessary.

. Remove any moisture in the air compressor air tank.

NEVER

attempt to open the Air Tank Drain Valve when more than 10

PSI is in the air tank! Remove excessive pressure with an air tool,

then open the Air Tank Drain Valve in the bottom of the air tank. Close

tightly when drained.

3. Make sure the Motor/Pressure Switch is in the "OFF" position.

4. Make sure the Safety Relief Valve is working correctly.

5. Make sure all guards and covers are in place and securely mounted.

DANGER

RISK OF ELECTROCUTION!

Improper connection of the

equipment-grounding conductor

can result in a risk of shock or

electrocution. Check with a

qualified electrician or service

personnel if you are in doubt as

to whether the outlet is properly

grounded. The wire with insulation

having an outer surface that is

green with or without yellow

stripes is the grounding wire.

WARNING

RISK OF ELECTRICAL SHOCK!
This product must be grounded. If

there should be a malfunction or

breakdown, grounding provides

a path of least resistance for

electric current to reduce the risk

of electric shock.

WARNING

RISK OF BODILY INJURY!

Never attempt to open the Air

Tank Drain Valve when more

than 10 PSI of air pressure is in

the air tank!

ELECTRICAL:

L1

L2

L3

G

L2

L1

Power

In

1 Phase

electric diagram_industrial line_1 Phase