John Deere AC2-80ES Manuel d'utilisation

Page 14

Advertising
background image

4

Stationary Electric Air Compressor Manual

OPERATING INSTRUCTIONS

START-UP:

. Read safety warnings before performing operation.
. Move the Motor/Pressure Switch to the "AUTO" position.
3. If you notice any unusual noise or vibration, stop the air compressor and refer

to "Troubleshooting".

SHUTDOWN:

. To stop the air compressor, move the Motor/Pressure Switch to the "OFF"

position.

. Drain air from the air tanks by releasing air with an attached air tool or by

pulling on the Safety Relief Valve.

3. Once the Air Tank Pressure Gauge registers under 0 pounds, open the Air

Tank Drain Valve under the air tank to drain any moisture.

4. Allow the air compressor to cool down, then wipe clean.

MAINTENANCE INSTRUCTIONS

Read the instruction manual before performing maintenance. The following

procedures must be performed when stopping the air compressor for maintenance

or service.
. Turn off air compressor.

. Open all drains after the tank gauge registers under 0 PSI..

3. Wait for the air compressor to cool before starting service.

WARNING

RISK OF BODILY INJURY!

Never assume the air

compressor is safe to work

on just because it is not

operating. It could restart at

any time!

*THE PUMP OIL MUST BE CHANGED AFTER THE FIRST 00 HOURS OF OPERATION AND EVERY 000

HOURS OR 3 MONTHS, WHICHEVER COMES FIRST.

EVERY TWO YEARS, AN AUTHORIzED SERVICE TECHNICIAN SHOULD CHECK THE CHECK VALVE, INTAKE

VALVES AND DELIVERY VALVES.

AC Ele. Maintenance Chart

MAINTENANCE CHART

PROCEDURE

DAILY

WEEKLY

MONTHLY

1000 HOURS

Check pump oil level

X

Oil leak inspection

X

Drain condensation in air tank (s)

X

Inspect guards/covers

X

Check for unusual noise/vibration

X

Check for air leaks

X

Clean exterior of compressor

X

Inspect air fi lter

X

Inspect belt

X

Check safety relief valve

X

Change pump oil *

X

Replace air fi lter

X

Advertising