Venting, Warning, Venting requirements – Maytag W10296136A-SP Manuel d'utilisation

Page 8

Advertising
background image

8

Dryer gas pipe

The gas pipe that comes out through the rear of your dryer

has a 3/8" male pipe thread.

29" Wide model

A

1¼"

(32 mm)

9¼"

(235 mm)

A. 3/8" NPT dryer pipe

27" Wide model

A

*6¼"

(159 mm)

1½"

(38 mm)

A. 3/8" NPT dryer pipe

A. 3/8" NPT dryer pipe

Burner input requirements

Elevations up to 10,000 ft. (3,048 m):

The design of this dryer is certified by CSA International for

use at altitudes up to 10,000 ft. (3,048 m), above sea level at

the B.T.U. rating indicated on the model/serial number plate.

Burner input adjustments are not required when the dryer is

operated up to this elevation.

Elevations above 10,000 ft. (3,048 m):

When installed above 10,000 ft. (3,048 m) a 4% reduction

of the burner B.T.U. rating shown on the model/serial

number plate is required for each 1,000 ft. (305 m)

increase in elevation.

gas supply pressure testing

The dryer must be disconnected from the gas supply piping

system during pressure testing at pressures greater than

1/2 psi.

venting Requirements

WARNING

Fire Hazard

use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death

or fire.

vEnTIng

WARnIng:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

ImPoRTAnT:

Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent,

chimney, wall, ceiling, attic, crawlspace, or a concealed space

of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure

exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid heavy metal

vent or flexible metal vent.

Review Vent system chart. Modify existing vent system if

necessary to achieve the best drying performance. Only rigid

or flexible metal vent shall be used for exhausting.

If this is a new vent system

vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (102 mm) heavy metal exhaust vent and clamps must be

used. DURASAFE™ venting products are recommended.

4" (102 mm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased by calling

the toll-free number. For further information, please reference

the “Assistance or Service” section of the “Dryer User

Instructions.”

Rigid metal vent:

For best drying performance, rigid metal vents are

recommended.
Rigid metal vent is recommended to avoid crushing and

kinking.

Flexible metal vent:

Flexible metal vents are acceptable only if accessible for

cleaning.