A. Standard rear offset exhaust installation

B. Left or right side exhaust installation

(27" wide models only)

C. Bottom exhaust installation (27" wide models only)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best

for your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

A

B

A. Over-The-Top installation (also available with

one offset elbow)

B. Periscope installation

noTE: The following kits for close clearance alternate

installations are available for purchase. Please see the

“Assistance or Service” section of the “Dryer User Instructions.”

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent

mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch

Part Number 4396011 - 18" (460 mm) to 29" (737 mm)

mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)

mismatch

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible

portion of the mobile home structure and must not terminate

beneath the mobile home. Terminate the exhaust vent outside.

C

D

Determine vent path:

Select the route that will provide straightest and most direct

path outdoors.
Plan the installation to use the fewest number of elbows and

turns.
When using elbows or making turns, allow as much room

as possible.
Bend vent gradually to avoid kinking.

Avoid 90° turns when possible.

Determine vent length and elbows needed for best
drying performance:

Use following Vent system chart to determine type of vent

material and hood combinations acceptable to use.
noTE: Do not use vent runs longer than those specified

in Vent system chart. Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

The Vent system chart provides venting requirements that will

help achieve best drying performance.

vent System Chart

number

90° turns or

elbows

Type of vent

Box/louvered

hoods

Angled hoods

0

Rigid metal

64 ft. (20 m)

58 ft. (17.7 m)

1

Rigid metal

54 ft. (16.5 m)

48 ft. (14.6 m)

2

Rigid metal

44 ft. (13.4 m)

38 ft. (11.6 m)

3

Rigid metal

35 ft. (10.7 m)

29 ft. (8.8 m)

4

Rigid metal

27 ft. (8.2 m)

21 ft. (6.4 m)

noTE: Side and bottom exhaust installations for 27" wide

models have a 90º turn inside the dryer. To determine maximum

exhaust length, add one 90º turn to the chart.

vent System Chart (29" Wide long vent models only)

number

90° turns or

elbows

Type of vent

Box, louvered,

or angled hoods

0

Rigid metal

120 ft. (36.6 m)

1

Rigid metal

110 ft. (33.5 m)

2

Rigid metal

100 ft. (30.5 m)

3

Rigid metal

90 ft. (27.4 m)

4

Rigid metal

80 ft. (24.4 m)

5

Rigid metal

70 ft. (21.3 m)