Gas dryer power hookup, Warning, Gas supply requirements – Maytag W10296136A-SP Manuel d'utilisation

Page 7

Advertising
background image

7

gAS DRYER PoWER HooKuP

gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure

gas pressure does not exceed 13" (330 mm) water

column.
Examples of a qualified person include:
licensed heating personnel,

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

gas type

natural gas:
This dryer is equipped for use with Natural Gas. It is design-

certified by CSA International for LP (propane or butane) gases

with appropriate conversion.

Your dryer must have the correct burner for the type of gas

in your home. Burner information is located on the rating

plate in the door well of your dryer. If this information does

not agree with the type of gas available, please reference

the “Assistance or Service” section of the “Dryer User

Instructions.”

lP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas

specified on the model/serial rating plate for use with a different

gas without consulting the serving gas supplier.

ImPoRTAnT: The gas installation must conform with local codes,

or in the absence of local codes, with the National Fuel Gas

Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and

Propane Installation Code, CSA B149.1.

gas supply line

1/2" NPT pipe is recommended.

3/8" approved tubing is acceptable for lengths under

20 ft. (6.1 m) if local codes and gas supplier permit.
Must include 1/8" NPT minimum plugged tapping accessible

for test gauge connection, immediately upstream of the gas

connection to the dryer (see illustration).

Must include a shutoff valve:

In the u.S.A.:
An individual manual shutoff valve must be installed within

six (6) feet (1.8 m) of the dryer in accordance with the

National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in

accordance with the B149.1, Natural Gas and Propane

Installation Code. It is recommended that an individual

manual shutoff valve be installed within six (6) feet (1.8 m)

of the dryer.

The shut off valve location should be easy to reach for opening

and closing.

A

B

E

D

C

A. 3/8" flexible gas connector

B. 3/8" pipe to flare adapter fitting

C. 1/8" NPT minimum plugged tapping

D. 1/2" NPT gas supply line

E. Gas shutoff valve

gas supply connection requirements

There are many methods by which your gas dryer can be

connected to the gas supply. Listed here are some guidelines

for two different methods of connection.

option 1 (Recommended method)
Flexible stainless steel gas connector:

If local codes permit, use a new flexible stainless steel gas

connector (Design Certified by the American Gas Association

or CSA International) to connect your dryer to the rigid gas

supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter

fitting between the stainless steel gas connector and the

dryer gas pipe, as needed to prevent kinking.

option 2 (Alternate method)
Approved aluminum or copper tubing:

Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing

(if codes and gas supplier permit).
If you are using Natural Gas, do not use copper tubing.

3/8" flare x 3/8" NPT adapter fitting between dryer pipe and

3/8" approved tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and a

different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP

compatible copper tubing can be used. If the total length

of the supply line is more than 20 ft. (6.1 m), use larger pipe.
noTE: Pipe joint compounds that resist the action of LP

gas must be used. Do not use TEFLON

®†

tape.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.