Electric dryer power hookup - canada only, Install leveling legs, Electrical requirements – Maytag W10296136A-SP Manuel d'utilisation

Page 6: Warning

Advertising
background image

6

4-wire receptacle (14-30R)

Do not use an extension cord.

If using a replacement power supply cord, it is recommended that

you use Power Supply Cord Replacement Part Number 3394208.

For further information, please reference the “Assistance or

Service” section of the “Dryer User Instructions.”

GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.

WARNING:

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.

ElECTRIC DRYER PoWER HooKuP - CAnADA onlY

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.

It is your responsibility:

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate

and in conformance with the Canadian Electrical Code,

C22.1-latest edition and all local codes. A copy of the

above codes standard may be obtained from: Canadian

Standards Association, 178 Rexdale Blvd., Toronto, ON

M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply on a separate 30-amp

circuit, fused on both sides of the line. A time-delay fuse or

circuit breaker is recommended. Connect to an individual

branch circuit.
This dryer is equipped with a CSA International Certified

Power Cord intended to be plugged into a standard 14-30R

wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure

wall receptacle is within reach of dryer’s final location.

InSTAll lEvElIng lEgS

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.

1. To avoid damaging the floor, use a large flat piece of

cardboard from the dryer carton. Place cardboard under the

entire back edge of the dryer. See illustration.

2. Firmly grasp the body of the dryer (not the console panel).

Gently lay the dryer on the cardboard. See illustration.

3. Examine the leveling legs. Find the diamond marking.

4. Screw the legs into the leg holes by hand. Use a wrench to

finish turning the legs until the diamond marking is no longer

visible.

5. Place a carton corner post under each of the 2 dryer back

corners. Stand the dryer up. Slide the dryer on the corner

posts until it is close to its final location. Leave enough room

to connect the exhaust vent.

6. Once connection is made and dryer is in final location,

remove corner posts and cardboard.

For mobile home use

Gas dryers must be securely fastened to the floor.

Mobile home installations require a Mobile Home Installation

Hold-down Kit. For ordering information please reference the

“Dryer User Instructions.”

Advertising