Controls–dip switches.

ge.com

The dip switch controls are located behind
the front case panel, through an opening
on the front of the unit.

To access the dip switches, remove the front
case panel by removing the filter, taking out
the four front screws, the upper two screws from
the top of the panel and the shipping screws on
each side, if present. (Discard the two side shipping
screws, if present).

NOTE: The owner is responsible for setting
the appropriate dip switches and connecting
terminals.

Controls–Dip Switches

Dip
Switches

All Electric Heat

(Heat pump models only)

When this switch is enabled (UP), heat pump
operation is locked out, causing the unit to provide
only electric resistance heat.

ALL I

2

R (All Electric Heat)

ALL I

2

R (All Electric Heat) (Heat-pump models only)

FREEZ S (Freeze Sentinel)

CONST FAN (Constant ON Fan)

TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)

TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)

No Function (Reserved for future use)
DUCT (Blower Fan)
OCCUPIED (Occupancy Sensor)