ELECTRICAL REQUIREMENTS

230/208 VOLT
ELECTRICAL SUPPLY

Tandem

15 Amp

230/208 volt receptacle configuration

Perpendicular

20 Amp

Large Tandem

30 Amp

Use ONLY the wiring size recommended for single

outlet branch circuit.

Proper current protection is the responsibility

of the owner.

A power supply kit must be used to supply power
to the Zoneline unit. The appropriate kit is determined
by the voltage, the means of electrical connection
and the amperage of the branch circuit. See the POWER
CONNECTION CHART on page 13 to select the appropriate kit.

All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations.

Power supply kit

Recommended branch circuit wire sizes*

Nameplate

maximum circuit

AWG Wire

breaker size

size**

15A

14

20A

12

30A

10

AWG – American Wire Gauge

*

Single circuit breaker from main box

** Based on copper wire, single insulated conductor at 60° C

NOTE: Use copper conductors only.

FOR 230/208 VOLT POWER CORD
CONNECTIONS ONLY

1. Remove the front panel by taking out the four

front screws, the upper two screws from the top
of the panel and the shipping screws on each side,
if present. (Discard the two side shipping screws,
if present.)

2. Remove the junction box cover and the junction box

and discard.

3. Connect the power cord, with a loop, through

the strain relief.

Strain relief

IMPORTANT:
Power cord must
have a loop.

Remove
junction box
and cover

Side
shipping
screw

Side
shipping
screw