MAKE UNIT ELECTRICAL
CONNECTIONS

1. Connect the thermostat wires to the unit and set

the dip switches to the appropriate settings.
NOTE: See the Controls–Terminal Connections

and Controls–Dip Switches sections
of this manual and the manual with
the separate thermostat for proper
connections and settings.

2. Make power connections to the unit.

NOTE: See the ELECTRICAL REQUIREMENTS and

DIRECT CONNECT APPLICATIONS sections,
as appropriate, of this manual for proper
connections.

3. Replace the case front panel by replacing the four

front screws and the two top screws.

6

Installation Instructions

Thermostat

Unit Connections

21

Maximum Wiring
Length for Thermostat
Connection to the Unit

66 ft. for AWG 18
60 ft. for AWG 20
40 ft. for AWG 24

AWG – American Wire Gauge

CONNECT THE TOP DUCT

1. Install the duct onto the air discharge outlet.

2. Secure the top duct to the unit by turning the four

case top duct adjusting screws until they are tight.
Use a field supplied clamp to lock the top duct
to the case.

7

Air
discharge
outlet

Rigid
ductwork

Inside
wall

Flexible or rigid
ductwork