F300E ELECTRONIC AIR CLEANER WITH ENHANCED FILTRATION

9

68-0240EF—3

Reassemble Air Cleaner

❑ Insert the electronic cells with the gray contact board

toward the power supply and the airflow arrow pointing

downstream. If the cell does not slide easily into the

cabinet, check the orientation of the cell key.

❑ Insert the metal mesh prefilters on the upstream side of the

cabinet in the guide provided.

❑ Insert the media postfilters on the downstream side of the

cabinet in the guide provided.

❑ Replace the access door. Insert the tab on the bottom of

the door into the slot in the cabinet, then swing it closed

and press into place. The door must be firmly in place or

the air cleaner will not operate.

Complete Wiring

WARNING

Electric Shock Hazard.

Can cause personal injury.

Do not use an extension cord.

• Assure all wiring complies with local codes and

ordinances.

• The line voltage power source must match the voltage and

frequency printed on the label inside the access door.

• When the System fan comes on, the Air Flow Switch (AFS)

senses the negative pressure in the duct and turns on the

power supply. If power to the air cleaner is controlled by

another switch, the AFS can be disabled by cutting the jumper

on the back of the AFS circuit board. See Fig. 9.

❑ Plug the electronic air cleaner directly into the correct

voltage and frequency outlet. See Fig. 9 for internal

schematic. The air cleaner operates correctly with any fan

when wired with conduit or plugged in.

NOTE: To reduce the risk of electric shock, this product has

a grounding type plug that has a third (grounding)

pin. This plug only fits into a grounding type power

outlet. If the plug does not fit into the outlet, contact a

qualified electrician to install the proper outlet. Do not

change the plug in any way.

Fig. 9. Internal schematic for electronic air cleaner with W8600F.

P3

P4

P1

P2

J3

BLACK

W4 W2 W1 W3

AIRFLOW SWITCH BOARD

ORANGE

GRAY

VIOLET

BLACK

1 INTERLOCK SWITCH.

2 SHORTING BAR.

3 AIRFLOW SWITCH DISABLE JUMPER.

4 NEON LIGHT.

M20830

POWER
SUPPLY

2

5

BLACK

BLACK

BLACK

BROWN

BLACK

BLACK

WHITE

GREEN

3

1

J4

J5

J1

BLACK

RED

TEST
BUTTON

CONTACT
BOARD

RED IONIZER

BLACK COLLECTOR

Advertising