F300E ELECTRONIC AIR CLEANER WITH ENHANCED FILTRATION

13

68-0240EF—3

Replacing Ionizer Wires

Broken or bent ionizer wires can cause an electrical short to

ground, often resulting in visible arcing or sparking. Do not

use cells until broken wires are removed. Cells can be used

temporarily with one wire missing, but replace the wire as

soon as possible.

Replacement wires are supplied cut to length with eyelets on

both ends for easy installation. See Parts and Accessories

Not Illustrated section. To install:

1. Hook the eyelet on one end of the wire over the spring

connector on one end of the cell. See Fig. 14. Be careful

to avoid damaging spring connectors or other parts of

the cells.

2. Hold the opposite eyelet with a needle nose pliers and

stretch the wire the length of the cell. Depress the

opposite spring connector and hook the eyelet over it.

3. Check the cell for short circuits using an ohmmeter; see

Fig. 15. Check the resistance between the frame of the

cell and both the ionizer and the collector contacts. In

each case, the resistance should be infinite.

Fig. 14. Replacing an ionizer wire.

Fig. 15. Use ohmmeter to check electronic cells for short

circuits.

Modification to Reduce Ozone Odor

CAUTION

Electric Shock Hazard.

Can cause personal injury.

Always disconnect power and open access door

before opening power supply cover.

The electronic air cleaner generates a small amount of ozone

in normal operation. During the first week or two of operation,

the amount may be higher because of sharp edges on some

of the new high voltage metal parts. Normal use quickly dulls

these edges.

The average person can detect the odor of ozone in

concentrations as low as 0.003 to 0.010 parts per million

(ppm). The electronic air cleaner contributes 0.005 to 0.010

ppm of ozone to the indoor air. The U.S. Food and Drug

Administration and Health and Welfare Canada recommend

that indoor ozone concentration should not exceed 0.050

ppm. As a comparison, the outdoor ozone level in major cities

is sometimes as high 0.100 ppm.

However, if desired, the ozone generated by the air cleaner

can be reduced in one of two ways:

1. Install an activated carbon filter downstream from the air

cleaner. Make sure particles from the air filter cannot fall

into the air cleaner.

M1540B

IONIZER
WIRE

IONIZER
WIRE

NEEDLENOSE
PLIERS

SPRING
CONNECTORS

PRESS
DOWN

EYELETS

REPLACING AN IONIZER WIRE.

TWO EYELETS HOLD IONIZER WIRE TO CELL.

1

1

COLLECTOR
TERMINAL

COLLECTOR
TERMINAL

IONIZER
TERMINAL

M6155