F300E ELECTRONIC AIR CLEANER WITH ENHANCED FILTRATION

7

68-0240EF—3

Offsets

If the duct connection to the furnace in a side installation

allows less than 7 in. (178 mm) for mounting the air cleaner

cabinet, add an offset to the elbow. See Fig. 4.

Fig. 4. Typical use of duct offset to allow space for

electronic air cleaner.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow them

could damage the product or cause a hazardous

condition.

2. Check the ratings given in the instructions and on the

product to make sure the product is suitable for your

application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

WARNING

Electric Shock Hazard.

Can cause electrical shock or equipment damage.

Do not connect to power before installation is

complete.

Unpack Electronic Air Cleaner

❑ Check that all components are included. The electronic air

cleaner is shipped assembled. The unit consists of a

galvanized steel cabinet, power supply with On-Off switch

and neon light, two electronic cells, two metal mesh

prefilters, two media postfilters, access door and product

data literature

❑ Order W8600F (optional) including mounting hardware and

installation literature separately.

❑ Order W8600A (optional) including mounting hardware,

batteries, and literature separately.

Clean Blower Compartment

❑ Remove and discard the existing furnace filter.

❑ Thoroughly clean the blower compartment.

❑ If possible, power vacuum the ductwork to remove

accumulated dust in an existing home, or construction dirt

in a new home. The electronic air cleaner cannot remove

dust that has settled in the blower compartment and

distribution ducts.

❑ Check the edges of the furnace fan blades for dirt buildup

and clean as necessary. The fan will not deliver the rated

cfm if the blades are dirty.

Fasten Cabinet To Furnace

NOTE: This procedure shows a side installation on a typical

highboy furnace. You may need to alter the proce-

dure to fit your application.

❑ Remove and set aside the access door, electronic cells

metal mesh prefilters and media postfilters.

❑ Align the cabinet with the return air opening.

❑ Create opening in furnace to match air cleaner cabinet

opening.

❑ Install a transition when the furnace and air cleaner

openings are different sizes. See Fig. 3.

❑ Place blocks under the cabinet so the unit is firmly

supported and level. The 5/8 in. (16 mm) mounting foot on

the cabinet hinge plate provides the minimum clearance

required for the access door hinge.

❑ Attach the cabinet securely to the furnace. The unit can be

attached directly, as shown, or a starting collar can first be

fitted in the furnace opening. Either drill holes and fasten

with sheet metal screws or rivets, or use slip joints. See

Fig. 5.

Fig. 5. Fasten cabinet to furnace.

M5627A

LESS
THAN
7 in.
[178 mm]

OFFSET

AT LEAST
7 in.
[178 mm]

1

1 TURNING VANES HELP DISTRIBUTE AIRFLOW EVENLY.

ELECTRONIC AIR

CLEAN

ER

TYPICAL USE OF DUCT OFFSET TO ALLOW
SPACE FOR ELECTRONIC AIR CLEANER.

M20804