Least sensitive most sensitive, Operation, Mode switching summary – Heath Zenith Carriage Light with Motion-activated 52-4474-4 Manuel d'utilisation

Page 6: Manual mode adjustment of coverage area, Specifications

Advertising
background image

6

598-1286-01

Note:

When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

* resets to Auto Mode at dawn.

Least Sensitive

Most Sensitive

The sensor is less sensitive to motion directly towards it

and more sensitive to motion across coverage area.

Sensor

Motion

Motion

OperatiOn

Mode:

On-Time

Works:

Day

Night

test

5 Seconds

x

x

auto

1, 5, or 10

Minutes

x

Manual

To Dawn*

x

MANUAL MODE

AUTO

TEST

ON-TIME Switch at 1, 5, or 10

minutes

... back on.

1 Second OFF

then...

Manual mode only works at night

because daylight returns the sensor

to AUTO.
Flip the light switch off for one sec-

ond then back on to toggle between

AUTO and MANUAL MODE.
Manual mode works only with the

ON-TIME switch in the 1, 5, or

10 position.

MODe sWitching suMMary

Flip light switch off for one

second then back on*

* If you get confused while switching modes, turn the power

off for one minute, then back on. After the calibration time

the control will be in the AUTO mode.

ManuaL MODe

aDjustMent OF cOverage area

The sensor on this light fixture detects “motion” by the

movement of heat across the coverage area. However,

following are examples of objects that also produce heat

and can cause the sensor to trigger:

• Pools of Water

• Air Conditioners

• Dryer Vents

• Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is triggering

the sensor, reduce the sensitivity.

speciFicatiOns

Range ...............................Up to 30 ft. (9.1 m) [varies with

surrounding temperature].

Sensing Angle...................180°

Electrical Load .................Up to 100 Watt Maximum

Tungsten Incandescent

Bulb Type .........................Medium Base, Type “A”, 100

Watt Maximum

Sensor Capacity ................360 Watt (3.0 A) Maximum

Tungsten Incandescent

Power Requirements .........120 VAC, 60 Hz

Operating Modes .............TEST, AUTO, and MANU-

AL MODE

ON-Timer ........................1, 5, 10 minutes

Test Timer ........................5 Seconds

Manual Mode Timer ........Dusk-to-Dawn

Advertising