598-1286-01

testing anD aDjustMents

1. Turn on the circuit breaker and light switch.

Note:

Sensor has a 1

1

/

2

minute warm up period before

it will detect motion. When first turned on wait 1

1

/

2

minutes.

2. Set:

ON-TIME switch to TEST

SENSITIVITY dial to Midway

3. Walk through the coverage area noting where you are

when the lights turn on. In TEST mode, light will stay

on for 5 seconds after sensing motion and then turn

off.

4. Adjust the SENSITIVITY to increase or decrease

the range as needed. Too much sensitivity may cause

false triggering due to heat sources in the coverage

area (see Adjustment of Coverage Area or Troubleshooting

section).

5. Set the amount of ON-TIME you want the light to stay

on after motion is detected (1, 5, or 10 minutes).

Maximum Range

Maximum

Coverage Angle*

(Top View)

FinaL asseMBLy

1. Push the wires into the junction box. Make sure none

of the wires get pinched.

2. Slide the fixture assembly onto the mounting screws.

Tighten decorative nuts removed in step 1 of Installation

section securely against fixture base.

Junction Box

Mounting Screw

Decorative Nut

3. Install one medium base light bulb (100 Watt maxi-

mum).

4. Place top cover onto fixture and attach using the two

decorative nuts (included). Hand tighten only.

5. After completing the tests on page 5, caulk around

fixture base with silicone weather sealant.

Top Cover

Decorative Nut

Light Bulb (100

Watt Maximum)

Fixture Assembly

Caulk Around

Fixture Base

TEST 1 5 10