15

6 - Conversion for LP or NG Gas

Proceed to Pressure Regulator Conversion noting the
LP / Propane position to complete the conversion.

After replacing the injectors adjust the burner flame (see Low
Flame Adjustment paragraph).
Check the appearance of each burner’s flame at HILO settings,
if the flame appears too large or too small make sure that all
steps were completed correctly.

Converting Appliances for Use with NG Gas

If this appliance should be converted for use with gas NG
(natural gas), each of the following modifications must be
performed.
1. Convert the pressure regulator to NG position as per the

section “Pressure Regulator Conversion”.

2. Replace all injectors following the step described on the

previous pages, observe the number stamped on the side,
this number corresponds to the orifice diameter and its
correct burner location (refer to the illustrations in section:
“Injectors Position”).

3. Adjust the burner flame (see Low Flame Adjustment section).

Check the appearance of each burner’s flame at HI - LO
settings, if the flame appears too large or too small make
sure that all steps were completed correctly.

Pressure regulator conversion

The appliances is designed for use with NG gas or LP gas. The
gas pressure regulator is supplied. It must be installed in the
gas supply line ahead of the manifold entrance.
It is pre-set for use with the gas as indicated on the appliance
label supplied with the appliance. For use with different gas
the appliance must be converted.
For the pressure regulator conversion follow the instructions
below:
• Disconnect all electrical power, at the main circuit breaker

or fuse box.

• Shut off the gas supply to the cooktop by closing the manual

shut-off valve.

• Adjust the pressure regulator, by following the instruction

(see figure)

1. Unscrew the regulator cap

2. Unscrew the plastic conversion plug from the cap turn

over and screw back (wide section away from cap for
LP and against cap for NG) see figures below.

3. Replace the regulator cap ensuring gasket is in place.

PRESSURE REGULATOR CONVERSION

NG

LP

NG POSITION

PLUG

PRESSURE REGULATOR

LP/PROPANE POSITION

GASKET

CAP

Before replacing the regulator cap, check if the position
of plug is suitable for the gas