You will need:

A water heater set to 120° F (49° C).

A grounded electrical outlet located within 4 ft. (0.9 m)

of power cord on back of washer.

Hot and cold water faucets located within 3 ft. (0.9 m)

of hot and cold water fill valves on washer, and water

pressure of 5-100 psi (34.5-690 kPa).

A level floor with maximum slope of 1" (25 mm) under entire

washer. Installing on carpet is not recommended.

Floor must support washer’s total weight (with water

and load) of 315 lbs (143 kgs).

IMPORTANT: Do not install, store, or operate washer where

it will be exposed to weather or in temperatures below 32° F

(0° C). Water remaining in washer after use may cause

damage in low temperatures. See “Washer Care” in your

“Use and Care Guide”. Proper installation is your responsibility.

Recessed area or closet installation

Dimensions show recommended spacing allowed, except for

closet door ventilation openings which are minimum required.

Consider allowing more space for ease of installation and

servicing, spacing for companion appliances and clearances

for walls, doors, and floor moldings. Add spacing of 1" (25 mm)

on all sides of washer to reduce noise transfer. If a closet door

or louvered door is installed, top and bottom air openings in

door are required.

3"

(76 mm)

3"

(76 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

19"

(483 mm)

1"

(25 mm)

0"

(0 mm)

4"

(102 mm)

14" max.

(356 mm)

DraIN systeM

Drain system can be installed using a floor drain, wall standpipe,

floor standpipe, or laundry tub. Select method you need.

IMPORTANT:

To avoid siphoning, no more than 4.5" (113 mm)

of drain hose should be inside standpipe or below the top of

wash tub. Secure drain hose with removable tie strap (A).

Minimum diameter for a standpipe drain: 2" (51 mm).

Minimum carry-away capacity: 17 gal. (64 L) per minute.

Some standpipes may require a Standpipe Adapter Kit and

additional drain hose that may be purchased separately. See

“Tools and Parts”. Top of standpipe must be at least 39" (991 mm)

high; install no higher than 96" (2.4 m) from bottom of washer.

Installations higher than 96" (2.4 m) require a sump pump system.

Wall standpipe drain system

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must

be at least 39" (991 mm) above floor; install no higher than

96" (2.4 m) from bottom of washer.

Floor drain system

Floor drain system requires a Siphon Break Kit and additional

drain hose that may be purchased separately. See “Tools and

Parts”. Minimum siphon break: 28" (711 mm) from bottom of

washer. (Additional hoses might be needed.)

Floor standpipe drain system

See requirements for floor standpipe drain system.

4.5"

(113 mm)

39"

(991 mm)

4.5"

(113 mm)

39"

(991 mm)

4.5"

(113 mm)

A

A

A