~XX105 1

7E 30 30 31 30 35 20 31 0D Advanced

Direct Power On

On

~XX105 0

7E 30 30 31 30 35 20 30 0D

Off (0/2 for backward compatible)

~XX106 n

7E 30 30 31 30 36 20 a 0D

Auto Power Off (min) n = 0 (a=30) ~ 180 (a=31 38 30)

~XX107 n

7E 30 30 31 30 37 20 a 0D Sleep Timer (min)

n = 0 (a=30) ~ 99

0

(a=39 39 39)

~XX115 1 7E 30 30 31 31 35 20 31 0D Quick Resume On

~XX115 0 7E 30 30 31 31 35 20 30 0D Off (0/2 for backward compatible)

~XX114 1

7E 30 30 31 31 34 20 31 0D

Power Mode(Standby) Eco.(<=0.5W)

~XX114 0

7E 30 30 31 31 34 20 30 0D

Active (0/2 for backward

compatible)

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

~XX109 1

7E 30 30 31 30 39 20 31 0D

Lamp Reminder

On

~XX109 0

7E 30 30 31 30 39 20 30 0D

Off (0/2 for backward compatible)

~XX110 1

7E 30 30 31 31 30 20 31 0D

Brightness Mode

Bright

~XX110 3

7E 30 30 31 31 30 20 33 0D Eco

+

~XX110 4

7E 30 30 31 31 30 20 34 0D Dynamic

~XX111 1

7E 30 30 31 31 31 20 31 0D

Lamp Reset

Yes

~XX111 0 7E 30 30 31 31 31 20 30 0D

No (0/2 for backward compatible)

~XX322 0 7E 30 30 33 32 32 20 30 0D Filter Reminder Off

~XX322 1 7E 30 30 33 32 32 20 31 0D 300 hr

~XX322 2 7E 30 30 33 32 32 20 32 0D 500 hr

~XX322 3 7E 30 30 33 32 32 20 33 0D 800 hr

~XX322 4 7E 30 30 33 32 32 20 34 0D 1000 hr

~XX323 1 7E 30 30 33 32 33 20 31 0D Filter Reset Yes

~XX323 0 7E 30 30 33 32 33 20 30 0D No

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

~XX112 1

7E 30 30 31 31 32 20 31 0D Reset

Yes

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

~XX99 1

7E 30 30 39 39 20 31 0D

RS232 Alert Reset

Reset System Alert

~XX210 n 7E 30 30 32 30 30 20 n 0D Display message on the OSD n: 1-30 characters

-----------------------------------------------------------------------------------------------------------------------------

SEND to emulate Remote

~XX140 10

7E 30 30 31 34 30 20 31 30 0D

Up

~XX140 11

7E 30 30 31 34 30 20 31 31 0D

Left

~XX140 12

7E 30 30 31 34 30 20 31 32 0D

Enter (for projection MENU)

~XX140 13

7E 30 30 31 34 30 20 31 33 0D

Right

~XX140 14

7E 30 30 31 34 30 20 31 34 0D

Down

~XX140 15

7E 30 30 31 34 30 20 31 35 0D

Keystone +

~XX140 16

7E 30 30 31 34 30 20 31 36 0D

Keystone –

~XX140 17

7E 30 30 31 34 30 20 31 37 0D

Volume –

~XX140 18

7E 30 30 31 34 30 20 31 38 0D

Volume +

~XX140 19

7E 30 30 31 34 30 20 31 39 0D

Brightness

~XX140 20

7E 30 30 31 34 30 20 32 30 0D

Menu

~XX140 21

7E 30 30 31 34 30 20 32 31 0D

Zoom

~XX140 28

7E 30 30 31 34 30 20 32 38 0D

Contrast

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SEND from projector automatically

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

232 ASCII Code

HEX Code

Function Projector

Return

Description

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

when Standby/Warming/Cooling/Out of

Range/Lamp fail/Fan Lock/Over Temperature/

Lamp Hours Running Out/Cover Open

INFOn

n : 0/1/2/3/4/6/7/8/ =

Standby/Warming/Cooling/Out

of Range/Lamp fail/Fan

Lock/Over Temperature/Lamp

Hours Running Out/Cover