READ ALL SAFETY INFORMATION BEFORE USING

1) All wiring must comply with local and national electrical
codes and must be installed by a qualified electrician. If you
have any questions regarding the following instructions, contact
a qualified electrician.

2) Check available power supply and resolve any wiring
problems BEFORE installing and operating this unit.

3) This 115V air conditioner uses 12.2 or less nameplate amps
and may be used in any properly wired, general purpose
household receptacle. See Table 1 for specifications for
individual branch circuit.

4) For your safety and protection, this unit is grounded through
the power cord plug when plugged into a matching wall outlet.
If you are not sure whether your wall outlet is properly
grounded, please consult a qualified electrician.

5) The wall outlet must match the 3-prong plug on the service
cord supplied with the unit. DO NOT use plug adapters. See
Table 2 for receptacle and fuse information. If it is necessary to
use an extension cord to connect your air conditioner, use an
approved “air conditioner” extension cord only
(available at
most local hardware stores).

6) The rating plate on the unit contains electrical and other
technical data. The rating plate is located on the right side of
the unit, above the power cord.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

15

14

AWG- American Wire Gauge

*Based on copper wire at 105°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

115

Amps

15

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)

IMPORTANT SAFETY INFORMATION

ELECTRICAL

SPECIFICATIONS

Control

Panel

Cabinet

Interior Air

Inlet

PART IDENTIFICATION