PROBLEM

POSSIBLE CAUSE

SOLUTION

• Unit does not work

• Air from unit does not feel cold
enough

• Air conditioner cooling but
room is too warm- ice forming
on cooling coil behind
decorative front.

• Air conditioner cooling but
room is too warm- NO ice form-
ing on cooling coil behind deco-
rative front.

• Air conditioner turns on and off
rapidly.

• Noise when unit is cooling.

• Water dripping INSIDE when
unit is cooling.

• Water dripping OUTSIDE
when unit is cooling.

• Remote Sensing
deactivating prematurely.

• Room too cold.

• Power is out
• The plug is not plugged in properly
• Plug current device tripped.

• Control is Off

• Room temp. below 17°C (62°F)

• Temp. sensing element touching cold
coil (behind air filter)
• Temp. set too high
• Compressor shut off by changing
modes

• Outdoor temp. below 17°C(62°F)
• Air filter may be dirty
• Thermostat too cold for night-time
cooling.

• Dirty air filter- air restricted
• Temp. is set too high
• Air directional louvers positioned
improperly
• Front of unit blocked(i.e. by drapes),
restricting air distribution.
• Doors, windows, registers etc. open,
cold air escaping.
• Unit recently turned on in hot room.

• Dirty air filter- air restricted
• Outside temp. extremely hot.

• Air movement sound

• Window vibration

• Improper installation

• Unit removing large quantity of
moisture from humid room.

• Remote control not located within
range.
• Remote control signal obstructed.

• Set temperature too low.

• Wait for power to return
• Plug in properly
• Press the reset button after

resolving problem

• Turn control ON and set to
desired setting.

• Will not cool until room temp. rises

above 17°C(62°F)
• Straighten tube away from coil.

• Reset to a lower temp.
• Wait approx. 3 minutes and listen for
compressor to restart when in cool
mode.

• To defrost coil, set to FAN ONLY

Clean filter as per instructions

• Set temp. to a higher setting

• Clean air filter
• Set to lower temp.
• Position louvers for better air
distribution.
• Clear blockage in front of unit

• Close doors, windows, registers.

• Allow additional time to remove
“stored heat” from room.

• Clean air filter.
• Set fan speed to higher setting to
bring air past cooling coils more
frequently.

• This is normal. If too loud, set to
slower fan setting.
• Poor installation- refer to installation
instructions or check with installer.

• Tilt air conditioner slightly to the out-
side to allow water drainage.

• This is normal during excessively
humid days.

• Place remote control within 20 feet &
180° radius of front of unit.
• Remove obstruction.

• Increase set temperature.

Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this
troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized
service depot or Danby’s Toll Free Number for assistance.