9.1 - Connecting
the boiler to an
indirect water
heater

This boiler, can be connected to
an indirect water heater. The water
connection must be made per fi gure
7-7. Heating pump item “9” of Figure
7-7 is mandatory for boiler model 160-
B. The electrical connections must be
made per fi gure 9-1. To change the
logic of the boiler, to drive and load an
indirect water heater, follow the steps
below while refering to Figure 9-2:
1. disconnect the boiler from the

electrical supply;

2. remove the boiler casing according

to the instructions given in section
14.2;

3. push the plastic spring tabs “B”;
4. open the front half of the electrical

box in the “C” direction;

9 - INSTALLATION - Connecting to an indirect water heater

5. move switch #1, item “D” to its “ON”

position as marked on the control
board;

6. move switch #5 in the OFF position;
7. on model 160-C, on the rear side

of the electrical junction box board,
if present, disconnect the plug with
two wires, item “E”, corresponding
to wires #44 and #45.

8. on model 160-C, on the rear side

of the electrical box, disconnect
the electrical plug from the diverter
valve (see Figure 3-1, item “35”).
When you disconnect the plug you
must insure that the boiler is in the
heating mode. If you are not sure,
light the boiler ON, wait the display
show “F” and then light-off the
boiler. Now you can disconnect the
plug from the diverter valve.

9. use a # 18 AWG two wire cable to

connect the indirect water heater
temperature sensor to terminals
“15” and “16”, as per Figure 9-1

10. insert the probe of the indirect

water heater sensor into the socket
of the indirect water heater.

WARNING!!!

Since the

indirect water heater temperature
sensor wires conduct 24 Vac,
they must never be run through
conduits containing 120 Vac
power wires or an electrical
shock hazard will exist.

WARNING!!!

Once the

boiler is connected to an indirect
water heater, it will perform a
weekly antilegionella cycle. This
cycle raises the water heater
temperature to 140°F one time
per week.

NOTE! A few cable conduit holes are

provided on the bottom right side of
the boiler

CAUTION!!!

If the pump is larger

than 1 hp or 2 amps, you must
isolate with a relay.

11. reinstall all dismounted parts.

Figure 9-1 Electrical connections for 160-B model (see Figure 7-7)

GROUND

NEUTRAL

120Vac LINE (HOT)

System pump (see
piping diagram of
Figure 7-7)

120Vac hot

Room
thermostat

Outdoor sensor (optional)

Indirect water heater sensor (optional)

Neutral

120Vac hot

Heating pump (see
piping diagram of
Figure 7-7)

Indirect water heater
pump (see piping
diagram of Figure 7-7)

Isolation relay