Installation Manual 9

Only use an upper side-wall exhaust vent on refrigerator models

that are equipped with a fan. If you use an upper side-wall exhaust

vent on a refrigerator model that is not equipped with a fan, the

refrigerator cooling performance will be poor.

- Make sure the refrigerator model is equipped with a fan.

- Install the upper side-wall exhaust vent [24] (See Art01592 and Art01593).

- For N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models, make sure the

distance [25] from the bottom of the enclosure to the top of the rough opening for the

upper exhaust vent is at least 55 inches.

- For N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX models, make sure the

distance [25] from the bottom of the enclosure to the top of the rough opening for the

upper exhaust vent is at least 62 inches.

- Align the upper exhaust vent [24] horizontally above the lower intake vent [9] of the

refrigerator.

- To prevent stagnant hot air in the area above the refrigerator, install an aluminum or

galvanized steel sheet baffle [13] between the top of the refrigerator and the top of the

upper exhaust vent.

- Make sure there is less than 1/4 inch clearance between the baffle and the top of

the refrigerator and that the baffle overlaps the refrigerator 1 inch or less.