ARC MASTER 175 SE INSTALLATION

INSTALLATION 3-2 Manual 0-5054

Arc Master 175 SE

13 AWG (1.5mm² )

230V/25A

175A@20%

-

230V/40A

-

175A@20%

Current & Duty Cycle

TIG STICK

Minimum Primary

Current Circuit Size

(Vin/Amps)

Model

Primary Supply Lead Size

(Factory Fitted)

Refer to Figure 1:
1. Connect end of ground (GREEN or GREEN/YELLOW) conductor to a suitable ground. Use a grounding method that

complies with all applicable electrical codes.

2. Connect ends of line 1 (BLACK) and line 2 (WHITE) input conductors to a de-energized line disconnect switch.
3. Use Table 3-1 as a guide to select line fuses for the disconnect switch

Input Voltage

Fuse Size

230V

40 Amps

Table 3-1: Electrical Connections

.

Fuse size is based on not more than 200 percent of the rated input amperage of the welding power source (Based on

Article 630, National Electrical Code).

Input Power

Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit provides

pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn on after the input capacitors

have charged to operating voltage (after approximately 5 seconds)

NOTE

Damage to the PCA could occur if 265 VAC or higher is applied to the Primary Power Cable.

Welding Power Supply

Figure 3-1: Electrical Input Connections

Table 3-2: Primary Supply Lead

Ground Terminal

Primary Power Cable

Line Fuse

Line Disconnect Switch

Ground Conductor

Art #: A-08462_AB