Installation – Regency Panorama P36E Medium Gas Fireplace Manuel d'utilisation

Page 20

Advertising
background image

P36E-4 Foyer à évent direct à dégagement zéro

20

Description

Simpson

Direct Vent Pro

®

Selkirk

Direct Temp™

American Metal

Products®

Amerivent Direct

Metal-Fab™

Sure Seal

Security

Secure- Vent®

ICC Excel

Direct

Attic Insulation Shield 12”

46DVA-IS

N/A@ FPI

N/A

4DAIS12

N/A

SV4RSA

N/A

Attic Insulation Shield -

Cold Climates

36”

N/A

N/A

4DAIS12

N/A

N/A

TM-4AS

High Wind Vertical Cap

46DVA-VCH

N/A

N/A

N/A

N/A

TM-4VT

High Wind Horizontal Cap

46DVA-HC

N/A

N/A

N/A

N/A

TM-4DHT

Horizontal Square Termination Cap

See

46DVA-HC

4DT-HHC

4DHC

4DHT

SV4CHC-1

TM-4HT

Vertical Termination Cap

N/A

4DT-HVC

4DVC

4DVT

SV4CGV-1

TM-4VT

Storm Collar

46DVA-08A

4DT-SC

4DSC

4DSC

SV4FC

TM-SC

Restrictor Disk

46DVA-RD

N/A

N/A

N/A

N/A

TM-4DS

Extended Vertical Termination Cap

46DVA-VCE

N/A

N/A

N/A

N/A

N/A

Chimney Conversion Kit A (USA only)

46DVA-KCA

N/A

N/A

N/A

N/A

TM-4CA6

Chimney Conversion Kit B (USA only)

46DVA-KCB

N/A

N/A

N/A

N/A

TM-4CA7

Chimney Conversion Kit C (USA only)

46DVA-KCC

N/A

N/A

N/A

N/A

TM-4CA8

Chimney Conversion Kit Masonry
(USA only)

46DVA-KMC

N/A

N/A

N/A

N/A

N/A

Wall Firestop

46DVA-WFS

N/A

N/A

N/A

N/A

TM-4TR

Colinear Flex Connectors

46DVA-ADF

N/A

N/A

N/A

N/A

N/A

Adjustable Flashing 0/12-6/12

N/A

4DT-ST14

4D12S

4DST14

SV4STC14

TF-4FA

Adjustable Flashing 6/12-12/12

N/A

4DT-ST36

4D36S

4DST36

SV4STC36

TF-4FB

Vinyl Siding Standoff

46DVA-VSS

4DT-VS

N/A

4DVS

SV4VS

TM-VSS

Vinyl Siding Shield Plate

N/A

4DT-VSP

N/A

N/A

SV4VS

N/A

Snorkel Termination 14”

46DVA-VCH

N/A

N/A

N/A

N/A

TM-4ST14

Snorkel Termination 36”

46DVA-HC

N/A

N/A

N/A

N/A

TM-4ST36

Basic Horizontal Termination Kit (A)

Disc.

4DT-HKA

4DHTK2

4DHTKA

SV-SHK

N/A

Horizontal Termination Kit (B)

46DVA-KHA

(Changed Components)

4DT-HKB

4DHTK1

4DHTKB

SV-HK

N/A

Vertical Termination Kit

Disc.

4DT-VKC

4DHTK

4DHTK

SV-FK

N/A

FPI

946-506/P

Vent Guard (Optional) for AstroCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adaptor (Must use with all rigid piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

946-605

Starter Collar Increaser 4” x 6-5/8” to 5” x 8”

946-206

Vinyl Siding Standoff for AstroCap

Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length

(L)

4” x 6-5/8” Venting

For specifi c instructions on venting components - visit the
manufacturers website listed below.

Run (X)

Rise (Y)

0” (0mm)

4-7/8” (124mm)

13-7/8” (340mm)

Simpson Direct Vent Pro: www.duravent.com

6” (152mm)

8” (203mm)

16-1/2” (419mm)

Selkirk Direct-Temp: www.selkirkcorp.com

9” (229mm)

10-1/8” (257mm)

18-5/8” (473mm)

American Metal Products: www.americanmetalproducts.com

12” (305mm)

12-1/4” (311mm)

20-3/4” (527mm)

Metal-Fab Sure Seal: www.mtlfab.com

24” (610mm)

20-5/8” (524mm)

29-1/8” (740mm)

Security Secure Vent: www.securitychimneys.com

36” (914mm)

29” (737mm)

37-1/2” (953mm)

Industrial Chimney Company: www.icc-rsf.com

48” (1219mm)

37-7/16” (951mm)

45-15/16” (1167mm)

INSTALLATION

Mettre les conduits d’évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu’à la sortie.
S’assurer qu’aucune section du système d’évacuation n’est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
un risque d'incendie.

Advertising