Assembly instructions continued – Garland GPD SERIES GAS PIZZA OVENS Manuel d'utilisation

Page 8

Advertising
background image

Part # 1844063 Rev 1 (01/30/07)

Page 8

ASSEMBLY INSTRUCTIONS Continued

Double Deck Assembly

1 x 4

LUMBER

FLUE
CONNECTOR

FIGURE 1

3/4 NIPPLE

3/4" COUPLING

3/4" x 3/4" x 1" TEE

6 1/2" NIPPLE

3/4" NIPPLE

3/4" COUPLING

1" NPT
90° STREET ELBOW

5 3/4" NIPPLE

3/4" UNION

3/4" NPT
90° STREET ELBOW

3/4" NPT
90° STREET ELBOW

1

Secure legs to lower section

2. Remove stainless steel top trim strip from lower unit if not

already removed.

3. Tip upper unit backward. Remove vent patch at lower

rear if not if not already removed.

4. Place 1” x 4” x 65” (25mm x 100mm x 1650mm) long piece

of lumber across the rear top of oven to prevent stacks
from misarranging.

5. Place the flue connector on the lower unit with extended

part to the right of the unit. (Fig 1)

6. Raise the top oven section up and onto the lower oven

section.

7. Carefully remove piece of lumber ensuring lower section

flue connector inserts into upper section vent hole.

8. Assemble the interconnecting gas piping as shown and

connect to rear gas inlets.

Gas Connection

1. The appliance must be isolated from the gas supply

piping system by closing its manual shut-off valve during
any pressure testing of the gas supply piping system at
test pressure equal to or less that 1/2 psig. (3.45 kpa.).

2. The appliance and its shut off valve must be

disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig. (3.45 kpa.).

NOTE: The ovens should not be installed on the same line

with space heaters, broilers or other equipment with high
intermittent demand.

3. When making gas connections, uses a pipe joint

compound that is resistant to the action of liquefied
petroleum gases.

4. Each oven is supplied with two possible gas connection

locations. One is located on the right side and the other is
located on the right rear corner.

5. The right side connection is plugged with a 3/4 counter

sunken plug. If this connection is used, you must cap the
rear connection.

6. The gas pressure regulator is part of the combination

valve and is adjusted to yield a pressure of 6.0” water
column for natural gas and 10” water column for propane
gas.

7. A separate shut-off valve for each oven must be provided.

It should be as close as possible to the place where the
gas line goes into the oven. It must be located so that it is
easily accessible. A handle or wrench should be chained
to the valve where it will always be at hand.

8. For a stack of two ovens, two shut-off valves, one for each

oven must be provided.

Advertising