Installation continued – Garland M/MST70 MASTER SERIES HEAVY DUTY GAS FRYERS Manuel d'utilisation

Page 9

Advertising
background image

Part # Rev 1.1382677 (11/12)

Page 9

INSTALLATION Continued

Assembly Instructions

M-Series Low Profile Backguard

1. Remove flue cap #6 by removing six (6) [#10] sheet metal

screws.

2. Remove front panel #5 by lifting upward.

3. With back panel #4 still attached to the left #2 and right

#3 uprights, drop uprights into the rectangular cutouts at

the rear of the range #1.

4. Fasten uprights #2 and #3 to the range #1 with four (4)

5/16” -18 bolts and flat washers #7 and #8.

5. If unit is in a battery lineup, fasten adjacent units together

at hole marked “X” with 1/4” -20 bolts, nuts, and washers.

6. Install front panel #5 previously remove.

7. Install flue cap #6 previously removed.

~

~

1

"X"

"X"

2

5

8

7

3

6

9

4

Assembly Instructions M-Series Backguard

1. Remove front panel #5 by lifting upward.

2. With back panel #4 still attached to the left #2 and right

#3 uprights, drop uprights into the rectangular cutouts at

the rear of the range.

3. Fasten uprights #2 and #3 to the range #1 with four (4)

5/16” -18 bolts and flat washers #6 and #7.

4. If unit is in a battery line up, fasten adjacent units

together at hole marked “X” with 1/4” -20 bolts and

washers.

5. Install front panel #5 previously removed. Attach front

panel #5 to range #1 with sheet metal screws.

1

"X"

"X"

2

5

8

4

3

6

7

Advertising