From Combustible material 6” (152mm) sides and rear. A

clearance of 0.0” to non combustible construction as sides

& rear is acceptable. The fryer is suitable for installation on

combustible floor.

Gas Connections and Piping Sizing

The size of the gas line is very important. If the line is too

small, the gas pressure at the burner manifold will be low.

This will cause slow recovery, delayed ignition, and pilot

outage. Refer to the Gas Line Sizing Chart in the nation Fuel

Codebook.

Before connecting new pipe to your GARLAND Fryer, the

pipe must be thoroughly blown out to depose of all foreign

particles. If these foreign particles get into the burner and

controls they will cause improper and sometimes dangerous

operation.

When using thread compound, use it sparingly and one on

male threads. Use compound that is impervious to the action

of Propane gases. Do not put any on the first two threads.

This will prevent fouling the controls and clogging the pilot

and main burner orifices.

Make sure that installer checks all plumbing with a soap

solution for leaks. DO NOT USE A FLAME, MATCHES,

CANDLES, or other ignition source in checking for leaks.

Frypot

Before leaving the factory, the fryer was tested, and the

thermostat was calibrated, with oil in the frypot; therefore,

it is necessary to clean the frypot before adding frying

compound. Rinse the frypot with clean water, then put some

fryer cleaner on a damp cloth, full strength, and wipe the

entire frypot clean. Rinse it thoroughly and wipe dry. The

fryer is now ready for use. If the fryer doe not have a stainless

steel frypot and is not to be used immediately after cleaning,

coat the entire frypot surface with shortening or cooking oil

to prevent rust.

Casters

A. The installation shall be made with a connector that

complies with the Standard for Connectors for Moveable

Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B-

2006/CSA 6.16B-2006 (or latest edition), and a quick-

disconnect device that complies with the Standard for

Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/

CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005 (or

latest edition).

B. The front casters of the unit are equipped with brakes

to limit the movement of the fryer without depending

on the connector and any quick disconnect device or its

associated piping to limit the appliance movement.

C. Please be aware, required restraint is attached to a

bracket on the fryer (connection point is located on the

left rear caster of the fryer), and if disconnection of the

restraint is necessary, be sure to reconnect the restraint

after the fryer has been returned to its originally installed

position.

NOTE: When installed, the fryer must be restrained to

prevent tipping in order to avoid the splashing of hot liquid.

The means of restraint may be the manner of installation,

such as connection to a battery of appliances. Or installing

the fryer in an alcove, or by separate means, such as

adequate ties.

Legs

Raise front of the unit and block. Do not lay unit on its back..

Position leg insert into leg retainer opening and tap up until

it seats at collar flange. Repeat at rear of unit making sure all

four legs are adjusted to same height. Legs can be adjusted

to overcome an uneven floor.

CAUTION: These types of GARLAND Fryers cannot be

installed on a masonry base or without proper clearance

from floor. Primary air is supplied to the ‘jet – type” burner

from the front and mainly from the bottom of the fryer. If

installed on a masonry base or directly on floor without

the use of the factory supplied 6” (152mm) legs or casters,

improper combustion will occur.