Det-Tronics X9800 IR Flame Detector with Pulse Output Manuel d'utilisation

Page 11

Advertising
background image

9

95-6555

5.1

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

+

(A) +290 Vcc
B - INPUT 1
B - INPUT 2
B - INPUT 3
B - INPUT 4
B - INPUT 5
B - INPUT 6
B - INPUT 7
B - INPUT 8
D1-1

oi DRIVER

D1-2

oi DRIVER

D1-3

oi DRIVER

D1-4

oi DRIVER

D1-5

oi DRIVER

D1-6

oi DRIVER

D1-7

oi DRIVER

D1-8

oi DRIVER

D2-1

oi DRIVER

D2-2

oi DRIVER

D2-3

oi DRIVER

D2-4

oi DRIVER

D2-5

oi DRIVER

D2-6

oi DRIVER

D2-7

oi DRIVER

D2-8

oi DRIVER

DMA OUT AVAILABLE
DMA OUT
DMA IN
DATA STROBE

33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64

ZONE OUTPUT 1
ZONE OUTPUT 2
ZONE OUTPUT 3
ZONE OUTPUT 4
ZONE OUTPUT 5
ZONE OUTPUT 6
ZONE OUTPUT 7
ZONE OUTPUT 8

FIRE LOGIC “A”

FIRE LOGIC “B”

ALARM OUTPUT

EXTERNAL RESET/INHIBIT

OUTPUTS INHIBITED

FAULT OUTPUT

EXTERNAL ACCEPT

STATUS & DET. OUTPUT S1
STATUS & DET. OUTPUT S2
STATUS & DET. OUTPUT S3
STATUS & DET. OUTPUT S4
STATUS & DET. OUTPUT S5
STATUS & DET. OUTPUT S6
STATUS & DET. OUTPUT S7
STATUS & DET. OUTPUT S8

DATA BUS 0
DATA BUS 1
DATA BUS 2
DATA BUS 3
DATA BUS 4
DATA BUS 5
DATA BUS 6
DATA BUS 7

CHASSIS (EARTH) GND

J1-7

J1-15

J1-5

J1-13

J1-6

J1-14

J1-8

J1-16

J1-9

J1-17

J1-10

J1-18

J1-11

J1-19

J2

CONTRÔLEUR R7404

J1

}

#2

#1

#19

#22

X9800

DÉTECTEUR 1

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 2

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 3

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 4

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 5

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 6

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 7

#2

#1

#19

#22

#2

#1

#19

#22

X9800

DÉTECTEUR 8

#2
#1
#19

#22

A2182

NOTE: SI LE PÔLE "-" DE L'ALIMENTATION NE PEUT PAS ÊTRE CONNECTÉ

A LA MASSE DU CHÂSSIS (TERRE), CONNECTER UNE CAPACITÉ

NON POLARISÉE DE 0,47µF 250 Vcc ENTRE J1-2 ET J2-64.

NOTE: 2,5 A SOUS 24 Vcc REQUIS POUR HUIT DÉTECTEURS.

NOTE: LES CIRCUITS DÉTECTEUR/CONTRÔLEUR SONT CONFORMES

AUX EXIGENCES DE CÂBLAGE CLASS B, STYLE 0.5

(LIGNES DE NOTIFICATION A ET C)

24

Vcc

+

62

63

64

VERS J1-2

0,47 μΦ / 400 Vcc

NON POLARISÉE

SYSTÈMES PROTÉGÉS
CONTRE LES DÉFAUTS DE MASSE

N° BORNE

FONCTION

1/11

TENSION cc - (FIL "C")

2/12

TENSION cc + (FIL "A")

19

SIGNAL (FIL "B")

22

oi

(FIL "D")

IDENTIFICATION DES BORNES POUR LE X9800

AVEC SORTIE IMPULSIONS

NOTE: NE PAS CONNECTER LE FIL "A" (#2/12) DU X9800

SUR LA BORNE J1-3 (290 Vcc)

DMA IN AVAILABLE

10 - 38 Vcc

Figure 6—Système Type, Détecteurs X9800 Câblés sur un Contrôleur R7404