1) installation, 2) positioning of the pond aerator pump, Pond aerator maintenance – Aquascape Pond Aerator (99449) Manuel d'utilisation

Page 4: 4) troubleshooting

Advertising
background image

4

*For replacement parts contact your local Aquascape Designs, Inc. supplier.

1) Installation

1. Install the pump in a covered, dry area close to a main power source.
2. Run the silicone air line to the pond.
3. Insert one end of the air line into the air pump outlet nozzles and the other into the air

stone which should then be placed in the pond.

4. Plug in the air pump.
5. Position the air stone to provide the best aeration and circulation in the pond.

2) Positioning of the Pond Aerator pump

1. Position the air pump on a firm surface, preferably higher than the water level of the

pond. If the pump is below the pond level than there is a chance water can back siphon

into the pump when the power is switched off or fails. If this happens it may cause the

pump to fail prematurely.

2. Ensure that the pump or main connection can not become wet or accidentally splashed.
3. Ensure that the pump is not placed on a surface with excessive dust or carpet fibers

which may block the air intake filter.

) Pond Aerator Maintenance

3.1 Cleaning Outside of Pump
• Disconnect pump from main power supply. Wipe down pump with a damp cloth and

mild detergent.

3.2 Pump Diaphragm
• There shouldn’t be any regular maintenance to the diaphragms. The diaphragms should

be replaced about once a year or when air output is greatly reduced. Spare diaphragms

can be purchased separately.

4) Troubleshooting

4.1 How to Avoid Loss of Airflow
If you have loss of airflow, check the following:
• Is the air filter blocked? This can happen if the pump is placed in a very dusty location or

near a carpet with loose fibers.

• Are there leaks in your air system? Check by immersing your air line in water to find the leak.
• Are there blockages in your air line? Air valves and air lines can become clogged over time.
• Is the air line kinked constricting air flow? Using silicone air line can help reduce kinks.
• Are the air stones clogged? Air stones can become clogged due to build up from dirt

or algae. Replacement air stones are available.

• Has excessive back pressure caused the diaphragm to tear, necessitating early replacement?

replacement Parts

Item#

Air Stones

02875

99448 Pond Aerator Instructions.4 4

6/2/06 10:14:22 AM

Advertising
Ce manuel est liée aux produits suivants: