2 control access, 1 inner access panel, 3 valve removal – Napoleon Fireplaces High Definition 81 - HD81 Manuel d'utilisation
Page 45

W415-0687 / G / 08.26.13
45
EN
NOTE: To install batteries in the case of a power outage you must access the
receiver. Remove the receiver cover plate and install the 4 “AA” batteries.
Ensure the 3 position slider switch is in the “REMOTE” position (middle).
(4) AA
Batteries
OFF REMOTE ON
NOTE: A new gasket will be
required, when re-installing the
access panel (see replacement
parts).
Remove one of the main doors,
see “DOOR REMOVAL /
INSTALLATION” section. Remove
either the optional brick or
porcelain panel from the side
where the control box is located.
Remove the eight screws from the
access panel.
11.2 CONTROL ACCESS
RETAINING
BRACKETS
ACCESS
PANEL
VALVE ACCESS
HOLE
11.2.1 INNER ACCESS PANEL
The valve on the HD81 is piped with three fl ex
connectors (one inlet, two outlets). It can be removed
and pulled forward for service.
A. Remove inner access panel, see “INNER ACCESS
PANEL” section.
B. Remove the wing nut and pivot the valve out from
the slot at the bottom of the valve.
C. Slowly pull the valve through the control door
being careful not to kink the gas lines or wires.
Disconnect fl ex connectors.
D. Replace all components before
returning the appliance to service.
E. Check for gas leaks by brushing on
a soap and water solution.
11.3 VALVE REMOVAL
CONTROL BOX
VALVE
WING
NUT
37.1A
•
Re-assemble the various components in reverse order.
•
Inspect the relief system. The appliance relief through the main glass door or through the fl aps on the
fi rebox top. Ensure they open freely, and close sealed.