IMPORTANT: The HD81 requires a minimum inside enclosure height of 84” (2134mm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the air.

5.4 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

84"

2132mm *

MINIMUM

ENCLOSURE

HEIGHT

50 1/2"

1283mm

MINIMUM

33 1/2"

851mm

MINIMUM

64 1/4"

1632mm

MINIMUM

PLUS RISE *

2" 51mm

2" 51mm

14"

356mm

MINIMUM **

MINIMUM

7 5/8"

194mm

COMBUSTIBLE

MATERIAL

TOP OF ENCLOSURE

BRICK

STEEL STUD

FRAMING

TOP OF

FIREPLACE

OPENING

0” (0mm) IF NON-

COMBUSTIBLE FINISHING

IS USED SUCH AS BRICK

AND STONE

* Refer to “VENTING” section.
** NOTE: Within the appliance enclosure a 3” (76mm) clearance between the vertical vent run and the combustible ma-
terials on the front facing of the enclosure is required. Similarly, a 14” (356mm) clearance to combustible materials from
the top of the horizontal vent run is required. All other clearances within the enclosure, including where the vent pipe
exits the enclosure are subject to 2” (51mm) for horizontal and 1” (25mm) for vertical.

!

WARNING

RISK OF FIRE!

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS

SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER

THE APPLIANCE OPENING.

THE STEEL STUD FRAMING KITS WITH CEMENT BOARD PROVIDED MUST BE INSTALLED.