Warning, Advertencia, Installation preparation – GE GLDT690DWW Manuel d'utilisation

Page 4: Prepare electrical wiring

Advertising
background image

4

Installation Preparation

PREPARE ELECTRICAL WIRING

WARNING

FOR PERSONAL SAFETY: Remove house

fuse or open circuit breaker before

beginning installation. Do not use an

extension cord or adapter plug with this

appliance.

ADVERTENCIA

ADVERTENCIA PARA SEGURIDAD

PERSONAL: Quite el fusible o abra el

interruptor de circuitos antes de comenzar

la instalación. No utilice un cable de

extensión o un enchufe adaptador con

este artefacto.

Electrical Requirements

•This appliance must be supplied with 120V, 60Hz., and

connected to an individual properly grounded branch

circuit, protected by a 15 or 20 ampere circuit breaker

or time delay fuse.

•Wiring must be 2 wire with ground.

•If the electrical supply does not meet the above

requirements, call a licensed electrician before

proceeding.

Grounding Instructions—Cable Direct

This appliance must be connected to a grounded metal,

permanent wiring system, or an equipment grounding

conductor must be run with the circuit conductors and be

connected to the equipment grounding terminal or lead on the

appliance.

Grounding Instructions—Power Cord Models

This appliance must be grounded. In the event of a

malfunction or breakdown, grounding will reduce the risk of

electrical shock by providing a path of least resistance for

electric current. The plug must be plugged into an appropriate

outlet that is installed and grounded in accordance with local

codes and ordinances.

WARNING

The improper connection of the

equipment grounding conductor can

result in a risk of electric shock. Check

with a qualified electrician or service

representative if you are in doubt that the

appliance is properly grounded.

ADVERTENCIA

La conexión inadecuada del conductor de

conexión a tierra del equipamiento puede

provocar un riesgo de descarga eléctrica.

Consulte a un electricista calificado o

representante de servicio técnico si tiene

dudas sobre la correcta conexión a tierra

del aparato.

Cabinet Preparation & Wire Routing
•The wiring may enter the opening from either side,
rear or the floor within the shaded area.
•Cut a 1-1/2” max. dia. hole to admit the electrical cable. The
hole must be free of sharp edges. If the cabinet wall is metal,
the hole edge must be covered with a bushing.
•Cable direct connections may pass through the same hole as
the drain hose and hot water line, if convenient. If cabinet wall
is metal, the hole edge must be covered with a bushing.
NOTE:

Power cords with plug must pass through a separate

hole.

Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher .
•For cable direct connections the cable must be routed as
shown in Figure 5. Cable must extend a minimum of 24”from
the rear wall.
•For power cord connections, install a 3-prong grounding type
receptacle. The power-supply receptacle for the appliance
shall be installed in a cabinet or on a wall adjacent to the
undercounter space in which the appliance is to be installed.

Figure 5

White

24"

from Wall

3"

from

Cabinet

Ground

Black

1-1/2" Dia.

Hole (Max.)

Advertising