Troubleshooting – GeneralAire M3 Manuel d'utilisation

Page 2

Advertising
background image

OWNER'S NAME
Nom du propriétaire:

MODEL M3 Humidistat
Humidistat MODÈLE M3

WARRANTY REGISTRATION
Enregistrement de la garantie

STREET ADDRESS
Adresse:

DEALER'S NAME
Nom du marchand:

DATE OF INSTALLATION / DATE DE INSTALLATION

CITY
Ville:

POSTAL CODE
Code postal:

STATE
Province:

STREET ADDRESS
Adresse:

CITY
Ville:

POSTAL CODE
Code postal:

STATE
Province:

FORM NO. M3-07 (FILE 13143)

Litho in U.S.A.

LIMITED WARRANTY

This humidistat, if properly registered by the return of the warranty registration card to the
manufacturer, is warranted to the consumer against defects in materials and workmanship for a
period of two years from the date of installation. Any defective parts will be repaired without
charge except for removal, reinstallation and transportation costs. To obtain repair service
under this limited warranty, the consumer must send the defective part or the complete
humidistat to the manufacturer.
THERE ARE NO EXPRESS WARRANTIES COVERING THIS HUMIDISTAT OTHER THAN
AS SET FORTH ABOVE, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR.
THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE
INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED
WARRANTY. THE MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
This limited warranty gives you specific legal rights, and you may also have other rights which
vary from state to state. Some states do not allow either limitations on implied warranties, or
exclusions from incidental or consequential damages, so the above exclusion and limitation
may not apply to you.
Any questions pertaining to this limited warranty should be addressed to the manufacturer.
(U.S.A.:The manufacturer has elected not to make available the informal dispute settlement
mechanism which is specified in the Magnuson-Moss Warranty Act.)

GENERAL FILTERS, INC.

CANADIAN GENERAL FILTERS, LTD.

43800 GRAND RIVER AVE.

39 CROCKFORD BLVD.

NOVI, MICHIGAN 48375-1115 SCARBOROUGH, ONTARIO M1R3B7
WWW.GENERALAIRE.COM WWW.CGFPRODUCTS.COM

TROUBLESHOOTING

SYMPTOM

DIAGNOSTIC STEPS

2 Check voltage at humidifier control terminals.
There should be no voltage for an Elite Room Steam
or a 1137 Power Humidifier.
Voltage should be 20-30 VAC for most others.

3 Inspect humidifier wiring. Refer to wiring diagrams.

DO NOT LEAVE IN "ON" POSITION, OVER HUMIDIFICATION MAY OCCUR.

1 Set thermostat to operate both furnace burner and blower.
Operation may be necessary for system power.

No Humidifier
Operation in
"ON" position

1 Humidity level in the home is higher than knob setting.
Humidifier control will not operate the humidifier until
humidity level is reduced.

Humidifier
operation in
"ON" position
only

1 When the humidity in the home is less than the knob
setting, the control will operate humidifier until the
humidity is higher. Reduce knob setting.

2 Use "ON" position. Verify that the humidifier operates.

1 Check voltage at humidifier control terminals.
There should be no voltage for an Elite Room Steam
or a 1137 Power Humidifier.
Voltage should be 20-30 VAC for most others.

2 If mounted on return air duct, make sure humidifier control
is at least 24" upstream of humidifier's air discharge.

Humidifier
turns on and
off repeatedly

3 Remove wires from control terminals, If humidifier
continues to operate, check solenoid valve.

Humidifier
operation
continuous

DIAGRAM 3

WIRING 120V. 1137 POWER HUMIDIFIER

HUMIDISTAT

SOLENOID VALVE

FAN

MOTOR

IS

O

L

A

T

IO

N

R

E

L

A

Y

BLK

WHT

YEL
YEL

120 V 60 HZ

WHT
BLK
BLK
BLU

G

G

G

H U M ID IS T A T

DIAGRAM 4

WIRING 230V. ELITE DUCT STEAM HUMIDIFIER

STEAM HUMIDIFIER
CONTROL MODULE

GO

G

TP

TP

ON

GND

DR

TAM

RELAY

1

RELAY

2

EV2

G

EV1

EV3

G

LS

LS

C

C

ID2

GND

ID1

SCR-

SCR+

+VR

SET

GND

AB

AB

R G V

DIP
Switch

FUSE

N O

C

TO FAN

FROM FAN
POWER SUPPLY

12500 AIR

PRESSURE

SWITCH

FACTORY

INSTALLED

JUMPER

FIELD SUPPLIED

2 POLE SINGLE

THROW RELAY

FACTORY
INSTALLED
JUMPER

HUMIDISTAT

DIAGRAM 5

WIRING 230V. ELITE ROOM STEAM HUMIDIFIER

+VR SET GND AB

AB

TERMINALS ON

ELITE STEAM BOARD