Installation clearances, Warning – John Wood Noritz Condensing - NRC111-DV (N-0842MC-DV) Manuel d'utilisation

Page 7

Advertising
background image

7

6.

Installation Clearances

Before installing, check for the following:

Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI
Z223.1/NFPA 54 – latest edition. In Canada, see NSCNGPIC for detailed requirements.

Item

Required Clearances

From Heater

• Maintain the following clearance from

both combustible and non-combustible
materials.

Check

Illustration

Securing of space for

repair/inspection

600mm
(24") or
more

200mm
(8") or
more

• If the unit will be installed in the vicinity of a

permanent kitchen range or stove that has
the possibility of generating steam that
contains fats or oils, use a dividing plate or
other measure to ensure that the unit is not
exposed to air containing such impurities.

* The dividing plate should be of noncombust-

ible material of a width greater than the
water heater.

Exhaust hood

Range

Dividing plate

Water
heater

Cooking Equipment

WARNING

200mm
(8") or
more

300mm (12") or more
(Indoor)
900mm (36") or more
(Outdoor)

100mm (4") or more
(Indoor)
600mm (24") or more
(Outdoor)

50mm (2") or more
(Indoor/Outdoor)

• If possible, leave 200mm (8") or more on

either side of the unit to facilitate inspection.

• If possible, leave 600mm (24") or more in

front of the unit to facilitate maintenance
and service if necessary.

• If possible, leave 75mm (3") or more above

and below the vent pipe to facilitate inspec-
tion and repair if necessary.

75mm (3") or more

75mm (3") or more