Figure 1 – Thermador PRD36 Manuel d'utilisation

Page 9

Advertising
background image

Page 6

Figure 1: Cabinet Clearances

For Electrical and Gas Supply Zone, see

Figure 3A.

Cooking
Surface

CAUTION: See

Figs. 2A and 2B

40" Min. to

combustible

material

Ð

,

from cooking

surface

as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). *The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.

Range width

30", 36", or 48"

30" or 36" Wide Hood

36" or 42" for Island
36" or 42" Wide Hood

42" or 48" for Island

}

}

For 30" Ranges

For 36" Ranges

Min. Distance Between Overhead Cabinets

of Combustible Material

30" Range – 30"

36" Range – 36"

48" Range - 48"

13" Max.

Cabinet

Depth

}

4" Min. to

combustible

side wall

material ,

(both sides)

18"

Min.

*35-7/8" Min. Range Height

with Leveling Legs fully

retracted

*36-3/4" Max. Range Height

with Leveling Legs fully

extended.

48", 54", or 60" Wide Hood

54" or 60" for Island

}

For 48" Ranges

36" from bottom of overhead
Hood to cooking surface
(40" min. if hood contains
combustible materials )