Figure 3a, Gas and electric supply, Page 9 – Thermador PRD36 Manuel d'utilisation

Page 12

Advertising
background image

Page 9

Gas and Electric Supply

Note: If not already present, install gas shut-off valve in an easily accessible location.

Make sure all users know where and how to shut off the gas supply to the range.

Note: The installer should inform the consumer of the location of the gas shut-off

valve.

Note: Any opening in the wall behind the appliance and any opening in the floor under the

appliance must be sealed.

The dual fuel ranges may be connected to the power supply with a range supply
cord kit or by hard-wiring to the power supply. It is the responsibility of the installer to
provide the proper wiring components (cord or conduit and wires) and complete the
electrical connection as dictated by local codes and ordinances, and/or the National
Electric Code. The units must be properly grounded. Refer to Step 6 for details.
Canadian models have power cord supplied.

The range must be connected only to the type of gas for which it is certified. If
the range is to be connected to propane gas, ensure that the propane gas supply
tank is equipped with its own high pressure regulator in addition to the pressure
regulator supplied with the range. (See Step 5.)

Figure 3a: Gas & Electrical Supply Locations for Dual Fuel Ranges

8 1/2"

6"

6 "

6"

6"

1 3/4"

30 1/4" (30" models)

36 1/4" (36" models)

1 3/4" maximum protrusion

from wall for gas or

electrical supply

electrical

supply zone

gas

supply zone

3"

2"

48-1/4”

2" maximum protrusion

from wall for gas or

electrical supply

Location of 240 VAC

Receptacle or Junction Box

4"

Location of hole for

Gas Supply Line

10"

4"

Gas & Electrical Supply Locations for 30” and 36” Dual Fuel Ranges

Gas & Electrical Supply Locations for 48” Dual Fuel Ranges